Kurz gefasst

Metaanalyse in der Zeitschrift The American Journal of Sports Medicine, 2023. Verfasst von Kyle N Kunze und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA. Hauptthemen laut MEDLINE: Rotator Cuff Injuries, Shoulder Joint. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Biodegradable subacromial balloon spacers (SBSs) have become increasingly used for the treatment of massive irreparable rotator cuff tears given their theorized clinical benefits; however, the relationship between biomechanical functions of the balloon spacer and clinical benefits remains unclear.

Purpose

To perform a systematic review and meta-analysis of controlled laboratory studies investigating the use of SBSs for massive irreparable rotator cuff tears. Study Design: Systematic review and meta-analysis; Level of evidence, 4.

Methods

PubMed, OVID/Medline, and Cochrane databases were queried in July 2022 for biomechanical data pertaining to SBS implantation in cadaveric models of irreparable rotator cuff tears. Random-effects meta-analysis of continuous outcomes using the DerSimonian-Laird method was performed to estimate pooled-treatment effect sizes between the irreparable rotator cuff tear state and the state in which an SBS was implanted. Data reported variably or in formats not amenable to analysis were presented descriptively.

Results

Five studies involving 44 cadaveric specimens were included. At 0° of shoulder abduction, SBS implantation resulted in a mean inferior humeral head translation of 4.80 mm (95% CI, 3.20-6.40; P < .001) relative to the irreparable rotator cuff tear state. This decreased to 4.39 mm and 4.35 mm at 30° and 60° of abduction, respectively. At 0° of abduction, implantation of an SBS was associated with a 5.01-mm (95% CI, 3.56-6.46, P < .001) anterior translation of the glenohumeral center of contact pressure relative to the irreparable tear state. This translation changed to 5.11 mm and 5.49 mm at 30° and 60° of abduction. In 2 studies, SBS implantation restored the glenohumeral contact pressure to that of the intact state and significantly reduced subacromial pressure distribution over a rotator cuff repair state. In 1 study, a high balloon fill volume (40 mL) resulted in a significant 10.3 ± 1.4–mm more anterior humeral head position relative to the intact cuff state.

Conclusion

SBS implantation in cadaveric models of irreparable rotator cuff tears results in significant improvements in humeral head position at 0°, 30°, and 60° of shoulder abduction. Balloon spacers may also improve glenohumeral and subacromial contact pressures, although insufficient evidence currently exists to corroborate these findings. High balloon fill volumes (40 mL) may confer supraphysiologic anteroinferior translation of the humeral head.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Rotator Cuff InjuriesShoulder JointHumansCadaverShoulderRuptureBiomechanical PhenomenaRange of Motion, Articular

Stichwörter der Autor:innen

balloonbiomechanicscadavericrotator cuff tearspacersubacromial balloon

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA.
  • Sports Medicine and Shoulder Institute, Hospital for Special Surgery, New York, New York, USA.
  • Yale School of Medicine, New Haven, Connecticut, USA.

ORCID-Profile: Kyle N Kunze, Jay Moran, Scott A Rodeo

Zitieren

APA

Kunze, K. N., Moran, J., Taylor, S. A., Fu, M. C., Rodeo, S. A., Warren, R. F., Dines, D. M., Gulotta, L. V., & Dines, J. S. (2023). Subacromial Balloon Spacer Implantation for Massive Irreparable Rotator Cuff Tears Is Associated With Restoration of the Acromiohumeral Interval and Glenohumeral Center of Pressure: A Systematic Review and Meta-Analysis of Controlled Laboratory Studies. The American Journal of Sports Medicine. https://doi.org/10.1177/03635465221150652

Vancouver

Kunze KN, Moran J, Taylor SA, Fu MC, Rodeo SA, Warren RF, et al. Subacromial Balloon Spacer Implantation for Massive Irreparable Rotator Cuff Tears Is Associated With Restoration of the Acromiohumeral Interval and Glenohumeral Center of Pressure: A Systematic Review and Meta-Analysis of Controlled Laboratory Studies. The American Journal of Sports Medicine. 2023. doi:10.1177/03635465221150652

BibTeX
@article{Kunze2023,
  author = {Kunze, Kyle N and Moran, Jay and Taylor, Samuel A and Fu, Michael C and Rodeo, Scott A and Warren, Russell F and Dines, David M and Gulotta, Lawrence V and Dines, Joshua S},
  title = {Subacromial Balloon Spacer Implantation for Massive Irreparable Rotator Cuff Tears Is Associated With Restoration of the Acromiohumeral Interval and Glenohumeral Center of Pressure: A Systematic Review and Meta-Analysis of Controlled Laboratory Studies},
  journal = {The American Journal of Sports Medicine},
  year = {2023},
  doi = {10.1177/03635465221150652}
}
Kostenlos starten →