Comparison of Shear Bond Strength of Different Wire-Composite Combinations for Lingual Retention: An in Vitro Study
Journal of Indian Orthodontic Society · 2019
DOI: 10.1177/0301574219840904 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Indian Orthodontic Society, 2019. Verfasst von Ananta Singh und 4 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
Context
As lingual bonded retainers are required for long-term retention in the oral cavity, the wire-composite combination of choice may be the determining factor for the success of lingual bonded retainers.
Aim
We compared the shear bond strength of different wire-composite combinations used for lingual bonded retainers and identified the combination of choice for lingual retention in terms of the shear bond strength. Materials and Methods: A total of 108 extracted human maxillary premolars in pairs were divided into 6 groups of 9 samples each. Three different types of retainer wires (namely, Respond [Ormco Corp., Orange, CA, USA], Leone Ligature Wire [Leone S.p.a., Firenze, Italy], and SRW™ Stranded Retention Wire [Ortho Classic Inc., USA]) were bonded to the teeth with the composites (G-aenial™ Universal Flo and Tetric N-Flow). The shear bond strength was measured on debonding using universal testing machine INSTRON.
Results
The maximum shear bond strength (58.28 N) was observed in group IV (Respond wire with Tetric N-Flow), whereas the minimum (25.28 N) was observed in group VI (SRW ™ Stranded Retention Wire with Tetric N-Flow). A highly significant difference was observed when the shear bond strength of group IV was compared with all the other groups.
Conclusions
The maximum shear bond strength was observed in the wire-composite combination of Respond dead-soft wire with Tetric N-Flow composite. Therefore, it could be the wire-composite combination of choice for bonded lingual retainer.
Zitieren
APA
Singh, A., Kapoor, S., Mehrotra, P., Bhagchandani, J., & Agarwal, S. (2019). Comparison of Shear Bond Strength of Different Wire-Composite Combinations for Lingual Retention: An in Vitro Study. Journal of Indian Orthodontic Society. https://doi.org/10.1177/0301574219840904
Vancouver
Singh A, Kapoor S, Mehrotra P, Bhagchandani J, Agarwal S. Comparison of Shear Bond Strength of Different Wire-Composite Combinations for Lingual Retention: An in Vitro Study. Journal of Indian Orthodontic Society. 2019. doi:10.1177/0301574219840904
BibTeX
@article{Singh2019,
author = {Singh, Ananta and Kapoor, Sudhir and Mehrotra, Praveen and Bhagchandani, Jitendra and Agarwal, Sonahita},
title = {Comparison of Shear Bond Strength of Different Wire-Composite Combinations for Lingual Retention: An in Vitro Study},
journal = {Journal of Indian Orthodontic Society},
year = {2019},
doi = {10.1177/0301574219840904}
}
EUVIMED