EUVIMEDEUVIMED entdecken
Crossref

T2* mapping of the patellofemoral joint at 3 T MRI: a repeatability and reproducibility study

Atilla Hikmet Cilengir iD, Ugurcan Suner iD, Yilmaz Onder iD, Tugrul Bulut iD, Merve Gursoy iD, Berna Dirim Mete iD

Acta Radiologica · 2026-06 · 67 (6) · 517-527

DOI: 10.1177/02841851261438071 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Radiologica, online erschienen am 20.04.2026. Verfasst von Atilla Hikmet Cilengir und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Department of Radiology, Izmir Democracy University, Izmir, Türkiye. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Patellofemoral Joint. Die Arbeit nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

T2* mapping provides objective data on chondromalacia. However, its reliability in evaluating both patellar and trochlear cartilages has not yet been established.

Purpose

To evaluate the repeatability and reproducibility of T2* mapping of patellar and trochlear cartilage in patients with patellofemoral maltracking, and to compare the reliability of axial and sagittal imaging planes for early detection of chondromalacia. Material and Methods This retrospective study included 106 knees from patients aged 18–40 years presenting with anterior knee pain and MRI evidence of patellofemoral malalignment between January 2023 and August 2025. T2* mapping was performed on a 3 T MRI scanner using standardized protocols. Patellar and trochlear cartilage were manually divided into 12 compartments in axial and sagittal planes. Regions of interest were placed manually, and T2* relaxation times were measured independently by a musculoskeletal radiologist and an orthopedic surgeon. Intra- and inter-observer reliability were assessed using intraclass correlation coefficients (ICCs).

Results

Most compartments demonstrated good-to-excellent intra- and inter-observer agreement (ICC ≥0.75), particularly in the upper and mid patellar cartilage zones. Axial-plane measurements consistently showed higher ICC values than sagittal-plane measurements. The lowest reliability was observed in lower cartilage zones and in sagittal-plane measurements. All results were statistically significant ( P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingPatellofemoral JointHumansReproducibility of ResultsFemaleAdultRetrospective StudiesYoung AdultMaleAdolescentCartilage, Articular

Stichwörter der Autor:innen

Cartilagemagnetic resonance imagingmappingpatellareliabilitytrochlea

Autor:innen und Institutionen

  • Faculty of Medicine, Department of Radiology, Izmir Democracy University, Izmir, Türkiye.
  • Department of Orthopedics and Traumatology, Van Training and Research Hospital, Van, Türkiye.
  • Department of Orthopedics and Traumatology, Izmir Katip Celebi University, Atatürk Training and Research Hospital, Izmir, Türkiye.
  • Department of Radiology, Acibadem Izmir Kent Hospital, Izmir, Türkiye.

ORCID-Profile: Atilla Hikmet Cilengir, Ugurcan Suner, Yilmaz Onder, Tugrul Bulut, Merve Gursoy, Berna Dirim Mete

Zitieren

APA

Cilengir, A. H., Suner, U., Onder, Y., Bulut, T., Gursoy, M., & Dirim Mete, B. (2026). T2* mapping of the patellofemoral joint at 3 T MRI: a repeatability and reproducibility study. Acta Radiologica, 67(6), 517-527. https://doi.org/10.1177/02841851261438071

Vancouver

Cilengir AH, Suner U, Onder Y, Bulut T, Gursoy M, Dirim Mete B. T2* mapping of the patellofemoral joint at 3 T MRI: a repeatability and reproducibility study. Acta Radiologica. 2026;67(6):517-527. doi:10.1177/02841851261438071

BibTeX
@article{Cilengir2026,
  author = {Cilengir, Atilla Hikmet and Suner, Ugurcan and Onder, Yilmaz and Bulut, Tugrul and Gursoy, Merve and Dirim Mete, Berna},
  title = {T2* mapping of the patellofemoral joint at 3 T MRI: a repeatability and reproducibility study},
  journal = {Acta Radiologica},
  year = {2026},
  volume = {67},
  number = {6},
  pages = {517--527},
  doi = {10.1177/02841851261438071}
}
Kostenlos starten →