Detection of microscopic fat in adrenal adenomas: comparison of 2D dual gradient-echo MRI and 3D two-point Dixon techniques
Acta Radiologica · 2025
DOI: 10.1177/02841851251358865 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Radiologica, 2025. Verfasst von Abdullah S Khan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of California, Davis Medical Center, Sacramento, CA, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Adrenal Gland Neoplasms, Adenoma, Imaging, Three-Dimensional. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
Background
Limited data exist comparing the detection of microscopic fat in adrenal adenomas on two-dimensional chemical shift dual-echo (2D CSI) magnetic resonance imaging (MRI) and three-dimensional two-point Dixon techniques (3D Dixon).
Purpose
To compare the sensitivity of 2D CSI versus 3D Dixon techniques for the diagnosis of adrenal adenomas. Material and Methods A retrospective analysis was conducted of 33 patients with adrenal masses who underwent both 2D CSI and 3D Dixon sequences on a 1.5-T scanner. Two blinded radiologists measured and calculated signal intensity (SI) index (SII) (100×(SI in phase – SI out of phase)/SI in phase) of nodules on each technique. Reference standard diagnosis of 30 adrenal adenomas was established. Sensitivity for adrenal adenoma diagnosis was determined using a SII >16.5%.
Results
In total, 33 nodules were investigated (mean size=22 mm, range=11–55 mm). Of the 30 adenomas, the mean SII on 2D CSI was 48% for reader 1 and 44% for reader 2, compared to 34% on 3D Dixon for both readers ( P < 0.001). Sensitivity for the diagnosis of adenoma with 2D CSI was 90% (95% confidence interval [CI]=82–98) for both readers, while 3D Dixon demonstrated a sensitivity of 73% (95% CI=65–82) for reader 1 and 63% (95% CI=55–72) for reader 2.
Conclusion
2D dual gradient-echo CSI demonstrated a higher sensitivity for the diagnosis of adrenal adenoma than the 3D Dixon technique. Adrenal MRI evaluation of the adrenal glands at 1.5 T should include 2D dual gradient-echo CSI and not rely solely on 3D two-point Dixon techniques for the diagnosis of adrenal adenomas.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of California, Davis Medical Center, Sacramento, CA, USA.
ORCID-Profile: Abdullah S Khan, Benjamin W Carney, Michael T Corwin
Zitieren
APA
Khan, A. S., Carney, B. W., & Corwin, M. T. (2025). Detection of microscopic fat in adrenal adenomas: comparison of 2D dual gradient-echo MRI and 3D two-point Dixon techniques. Acta Radiologica. https://doi.org/10.1177/02841851251358865
Vancouver
Khan AS, Carney BW, Corwin MT. Detection of microscopic fat in adrenal adenomas: comparison of 2D dual gradient-echo MRI and 3D two-point Dixon techniques. Acta Radiologica. 2025. doi:10.1177/02841851251358865
BibTeX
@article{Khan2025,
author = {Khan, Abdullah S and Carney, Benjamin W and Corwin, Michael T},
title = {Detection of microscopic fat in adrenal adenomas: comparison of 2D dual gradient-echo MRI and 3D two-point Dixon techniques},
journal = {Acta Radiologica},
year = {2025},
doi = {10.1177/02841851251358865}
}
EUVIMED