Usefulness of the fast spin-echo multi-point Dixon image of the knee joint on 3.0 T MRI for evaluation of meniscal tear
Acta Radiologica · 2025
DOI: 10.1177/02841851251347780 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Radiologica, 2025. Verfasst von Sumin Park und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Tibial Meniscus Injuries. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
Background
It remains unclear whether a torn meniscus loses significantly more fat content than a normal meniscus and consequently shows a lower signal drop on opposed-phase (OP) images using the multi-point Dixon (mDixon) technique.
Purpose
To evaluate meniscal injuries by performing a quantitative analysis of internal fat content using a signal drop. Material and Methods A total of 99 patients who underwent knee magnetic resonance imaging (MRI) with the mDixon technique was included in this retrospective study. We measured the mean signal intensity of the meniscus from the in-phase (IP) and OP mDixon images with sagittal reconstruction. The proportional decrease of signal intensity (signal drop) was calculated. The median value with 25th (Q1) and 75th (Q3) percentiles of signal drop was reported for each meniscus. The Mann–Whitney U-test was used to compare the signal drop between meniscal tear and normal groups.
Results
In the lateral meniscus (LM) and medial meniscus posterior horn (MMPH) tear groups, the median values of signal drop were significantly lower than in the normal group ( P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
ORCID-Profile: Sumin Park, Hee Jin Park
Zitieren
APA
Park, S., Park, H. J., & Kim, J. N. (2025). Usefulness of the fast spin-echo multi-point Dixon image of the knee joint on 3.0 T MRI for evaluation of meniscal tear. Acta Radiologica. https://doi.org/10.1177/02841851251347780
Vancouver
Park S, Park HJ, Kim JN. Usefulness of the fast spin-echo multi-point Dixon image of the knee joint on 3.0 T MRI for evaluation of meniscal tear. Acta Radiologica. 2025. doi:10.1177/02841851251347780
BibTeX
@article{Park2025,
author = {Park, Sumin and Park, Hee Jin and Kim, Ji Na},
title = {Usefulness of the fast spin-echo multi-point Dixon image of the knee joint on 3.0 T MRI for evaluation of meniscal tear},
journal = {Acta Radiologica},
year = {2025},
doi = {10.1177/02841851251347780}
}
EUVIMED