Feasibility of preventing massive contrast media extravasation using a sensor device in contrast-enhanced CT: an observational study
Acta Radiologica · 2024-11 · 65 (11) · 1325-1331
DOI: 10.1177/02841851241287314 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Acta Radiologica, online erschienen am 16.10.2024. Verfasst von Yoriaki Matsumoto und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hiroshima University Hospital, Hiroshima, Japan. Hauptthemen laut MEDLINE: Extravasation of Diagnostic and Therapeutic Materials, Contrast Media, Tomography, X-Ray Computed, Feasibility Studies. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
Background
Recent guidelines recommend direct patient observation, pressure monitoring, and sensor devices to prevent extravasation during contrast media (CM) injection. However, it is impractical in terms of time and cost to install sensors for all patients.
Purpose
To identify risk factors for CM extravasations during contrast-enhanced computed tomography (CECT) in a large population and to establish criteria for placing the sensor device on patients. Material and Methods This retrospective study included 143,556 patients who underwent CECT at our hospital between April 2012 and July 2022. We performed multivariable logistic regression analysis between patients with (n = 350) and randomly selected patients without CM extravasation (n = 350). We investigated the percentage of patients with sensor devices and their sensitivity for detecting extravasation using receiver operating characteristic curve analysis.
Results
The extravasation rate was 0.27%. Multivariable logistic regression analysis showed that the injection rate (adjusted odds ratio [AOR] = 1.61, 95% confidence interval [CI] = 1.33–1.95: P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Hiroshima University Hospital, Hiroshima, Japan.
- Department of Nursing, Hiroshima University Hospital, Hiroshima, Japan.
- Department of Epidemiology, Infectious Disease Control and Prevention, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
- Department of Diagnostic Radiology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
ORCID-Profile: Yoriaki Matsumoto
Zitieren
APA
Matsumoto, Y., Chikasue, A., Kondo, M., Akita, T., Kiguchi, M., Nakamura, Y., & Awai, K. (2024). Feasibility of preventing massive contrast media extravasation using a sensor device in contrast-enhanced CT: an observational study. Acta Radiologica, 65(11), 1325-1331. https://doi.org/10.1177/02841851241287314
Vancouver
Matsumoto Y, Chikasue A, Kondo M, Akita T, Kiguchi M, Nakamura Y, et al. Feasibility of preventing massive contrast media extravasation using a sensor device in contrast-enhanced CT: an observational study. Acta Radiologica. 2024;65(11):1325-1331. doi:10.1177/02841851241287314
BibTeX
@article{Matsumoto2024,
author = {Matsumoto, Yoriaki and Chikasue, Ayaka and Kondo, Miho and Akita, Tomoyuki and Kiguchi, Masao and Nakamura, Yuko and Awai, Kazuo},
title = {Feasibility of preventing massive contrast media extravasation using a sensor device in contrast-enhanced CT: an observational study},
journal = {Acta Radiologica},
year = {2024},
volume = {65},
number = {11},
pages = {1325--1331},
doi = {10.1177/02841851241287314}
}
EUVIMED