EUVIMEDEUVIMED entdecken
Crossref

Silicone implant and fibrous capsule assessment based on water-fat-silicone chemical shift encoding-based species separation in breast MRI

Tabea Borde iD, Jonathan Stelter, Antonia Wiedemann, Christof Böhm, Stefan Ruschke, Alexander Komenda, Kilian Weiss, Mingming Wu, Marcus R Makowski, Dimitrios C Karampinos, Eva M Fallenberg

Acta Radiologica · 2024

DOI: 10.1177/02841851241258402 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Radiologica, 2024. Verfasst von Tabea Borde und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, School of Medicine & Health, Technical University of Munich, Munich, Germany. Hauptthemen laut MEDLINE: Breast Implants, Magnetic Resonance Imaging, Silicones. Die Arbeit nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

With rising breast augmentations worldwide, there is an increasing clinical need for an early and accurate detection of implant complications.

Purpose

To compare the quality of chemical shift encoding-based (CSE) water-fat-silicone separation compared to double inversion recovery (DIR) silicone-only imaging in breast magnetic resonance imaging (MRI). Material and Methods This retrospective, single-center study included women with silicone implants subjected to 3-T MRI between January 2021 and March 2022. MRI included (i) two-dimensional silicone-only T2-weighted turbo spin echo DIR acquisition and (ii) three-dimensional CSE imaging based on multi-echo gradient-echo sequence enabling water-, fat-, and silicone-image separation. Images were evaluated and compared by three independent radiologists using a clinically established rating including differentiability of the silicone implant, visibility and contouring of the adjacent fibrous capsule, and accuracy of intralesional folds in a ranking of 1–5. The apparent contrast-to-noise (aCNR) was calculated.

Results

In 71 women, the average quality of water-fat-silicone images from CSE imaging was assessed as “good” (assessment 4 ± 0.9). In 68 (96%) patients, CSE imaging achieved a concise delineation of the silicone implant and precise visualization of the fibrous capsule that was not distinguishable in DIR imaging. Implant ruptures were more easily detected in CSE imaging. The aCNR was higher in CSE compared to DIR imaging (18.43 ± 9.8 vs. 14.73 ± 2.5; P = 0.002).

Conclusion

Intrinsically co-registered water-fat-silicone-separated CSE-based images enable a reliable assessment of silicone implants. The simultaneously improved differentiability of the implant and fibrous capsule may provide clinicians with a valuable tool for an accurate evaluation of implant integrity and early detection of potential complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast ImplantsMagnetic Resonance ImagingSiliconesHumansFemaleRetrospective StudiesAdultMiddle AgedBreastWaterAdipose TissueSilicone GelsAged

Stichwörter der Autor:innen

Breastbreast implantsmagnetic resonance imagingsilicone gel

Substanzen

SiliconesWaterSilicone Gels

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, School of Medicine & Health, Technical University of Munich, Munich, Germany.
  • Philips GmbH Market DACH, Hamburg, Germany.

ORCID-Profile: Tabea Borde

Zitieren

APA

Borde, T., Stelter, J., Wiedemann, A., Böhm, C., Ruschke, S., Komenda, A., Weiss, K., Wu, M., Makowski, M. R., Karampinos, D. C., & Fallenberg, E. M. (2024). Silicone implant and fibrous capsule assessment based on water-fat-silicone chemical shift encoding-based species separation in breast MRI. Acta Radiologica. https://doi.org/10.1177/02841851241258402

Vancouver

Borde T, Stelter J, Wiedemann A, Böhm C, Ruschke S, Komenda A, et al. Silicone implant and fibrous capsule assessment based on water-fat-silicone chemical shift encoding-based species separation in breast MRI. Acta Radiologica. 2024. doi:10.1177/02841851241258402

BibTeX
@article{Borde2024,
  author = {Borde, Tabea and Stelter, Jonathan and Wiedemann, Antonia and Böhm, Christof and Ruschke, Stefan and Komenda, Alexander and Weiss, Kilian and Wu, Mingming and Makowski, Marcus R and Karampinos, Dimitrios C and Fallenberg, Eva M},
  title = {Silicone implant and fibrous capsule assessment based on water-fat-silicone chemical shift encoding-based species separation in breast MRI},
  journal = {Acta Radiologica},
  year = {2024},
  doi = {10.1177/02841851241258402}
}
Kostenlos starten →