EUVIMEDEUVIMED entdecken
Crossref

Epicardial adipose tissue (EAT) thickness on non-gated chest CT as an alternative to EAT volume on cardiac CT

Murat Vural, Betül Akdal Dölek iD, Gülsüm Kılıçkap iD, Gülsüm Kübra Bahadır, Yasin Celal Güneş

Acta Radiologica · 2024

DOI: 10.1177/02841851241246626 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Radiologica, 2024. Verfasst von Murat Vural und 4 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, T.C. Ministry of Health, Ankara Bilkent City Hospital, Ankara, Türkiye. Hauptthemen laut MEDLINE: Adipose Tissue, Pericardium, Tomography, X-Ray Computed, Radiography, Thoracic. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Epicardial adipose tissue (EAT) volume is usually measured with ECG-gated computed tomography (CT). Measurement of EAT thickness is a more convenient method; however, it is not clear whether EAT thickness measured with non-gated CT is reliable and at which localization it agrees best with the EAT volume.

Purpose

To examine the agreement between ECG-gated EAT volume and non-gated EAT thickness measured from various localizations and to assess the predictive role of EAT thickness for high EAT volume. Material and Methods EAT thickness was measured at six locations using non-contrast thorax CT and EAT volume was measured using ECG-gated cardiac CT (n = 68). The correlation and agreement (Bland–Altman plots) between the thicknesses and EAT volume were assessed.

Results

EAT thicknesses were significantly correlated with EAT volume ( P < 0.001). The highest correlation (r = 0.860) and agreement were observed for the thickness adjacent to the right ventricular free wall. Also, EAT thickness at this location has a strong potential for discriminating high (>125 cm 3 ) EAT volume (area under the ROC curve=0.889, 95% CI=0.801–0.977; P < 0.001). The sensitivity, specificity, and positive and negative predictive values of EAT thickness for high EAT volume were 76.5%, 88.2%, 68.4%, and 91.8%, respectively, for the cutoff value of 5.75 cm; and 47.1%, 100%, 100%, and 85%, respectively, for the cutoff value of 8.10 cm.

Conclusion

EAT thickness measured on non-gated chest CT adjacent to the right ventricular free wall is a reliable and easy-to-use alternative to the volumetric quantification and has a strong potential to predict high EAT volume.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Adipose TissuePericardiumTomography, X-Ray ComputedRadiography, ThoracicHumansMaleFemaleMiddle AgedAgedAdultReproducibility of ResultsAged, 80 and overEpicardial Adipose Tissue

Stichwörter der Autor:innen

Computed tomographycardiovascular riskdiagnosticepicardial adipose tissuegating

Autor:innen und Institutionen

  • Radiology Department, T.C. Ministry of Health, Ankara Bilkent City Hospital, Ankara, Türkiye.

ORCID-Profile: Betül Akdal Dölek, Gülsüm Kılıçkap

Zitieren

APA

Vural, M., Dölek, B. A., Kılıçkap, G., Kübra Bahadır, G., & Celal Güneş, Y. (2024). Epicardial adipose tissue (EAT) thickness on non-gated chest CT as an alternative to EAT volume on cardiac CT. Acta Radiologica. https://doi.org/10.1177/02841851241246626

Vancouver

Vural M, Dölek BA, Kılıçkap G, Kübra Bahadır G, Celal Güneş Y. Epicardial adipose tissue (EAT) thickness on non-gated chest CT as an alternative to EAT volume on cardiac CT. Acta Radiologica. 2024. doi:10.1177/02841851241246626

BibTeX
@article{Vural2024,
  author = {Vural, Murat and Dölek, Betül Akdal and Kılıçkap, Gülsüm and Kübra Bahadır, Gülsüm and Celal Güneş, Yasin},
  title = {Epicardial adipose tissue (EAT) thickness on non-gated chest CT as an alternative to EAT volume on cardiac CT},
  journal = {Acta Radiologica},
  year = {2024},
  doi = {10.1177/02841851241246626}
}
Kostenlos starten →