Epicardial adipose tissue (EAT) thickness on non-gated chest CT as an alternative to EAT volume on cardiac CT
Acta Radiologica · 2024
DOI: 10.1177/02841851241246626 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Radiologica, 2024. Verfasst von Murat Vural und 4 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, T.C. Ministry of Health, Ankara Bilkent City Hospital, Ankara, Türkiye. Hauptthemen laut MEDLINE: Adipose Tissue, Pericardium, Tomography, X-Ray Computed, Radiography, Thoracic. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Background
Epicardial adipose tissue (EAT) volume is usually measured with ECG-gated computed tomography (CT). Measurement of EAT thickness is a more convenient method; however, it is not clear whether EAT thickness measured with non-gated CT is reliable and at which localization it agrees best with the EAT volume.
Purpose
To examine the agreement between ECG-gated EAT volume and non-gated EAT thickness measured from various localizations and to assess the predictive role of EAT thickness for high EAT volume. Material and Methods EAT thickness was measured at six locations using non-contrast thorax CT and EAT volume was measured using ECG-gated cardiac CT (n = 68). The correlation and agreement (Bland–Altman plots) between the thicknesses and EAT volume were assessed.
Results
EAT thicknesses were significantly correlated with EAT volume ( P < 0.001). The highest correlation (r = 0.860) and agreement were observed for the thickness adjacent to the right ventricular free wall. Also, EAT thickness at this location has a strong potential for discriminating high (>125 cm 3 ) EAT volume (area under the ROC curve=0.889, 95% CI=0.801–0.977; P < 0.001). The sensitivity, specificity, and positive and negative predictive values of EAT thickness for high EAT volume were 76.5%, 88.2%, 68.4%, and 91.8%, respectively, for the cutoff value of 5.75 cm; and 47.1%, 100%, 100%, and 85%, respectively, for the cutoff value of 8.10 cm.
Conclusion
EAT thickness measured on non-gated chest CT adjacent to the right ventricular free wall is a reliable and easy-to-use alternative to the volumetric quantification and has a strong potential to predict high EAT volume.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiology Department, T.C. Ministry of Health, Ankara Bilkent City Hospital, Ankara, Türkiye.
ORCID-Profile: Betül Akdal Dölek, Gülsüm Kılıçkap
Zitieren
APA
Vural, M., Dölek, B. A., Kılıçkap, G., Kübra Bahadır, G., & Celal Güneş, Y. (2024). Epicardial adipose tissue (EAT) thickness on non-gated chest CT as an alternative to EAT volume on cardiac CT. Acta Radiologica. https://doi.org/10.1177/02841851241246626
Vancouver
Vural M, Dölek BA, Kılıçkap G, Kübra Bahadır G, Celal Güneş Y. Epicardial adipose tissue (EAT) thickness on non-gated chest CT as an alternative to EAT volume on cardiac CT. Acta Radiologica. 2024. doi:10.1177/02841851241246626
BibTeX
@article{Vural2024,
author = {Vural, Murat and Dölek, Betül Akdal and Kılıçkap, Gülsüm and Kübra Bahadır, Gülsüm and Celal Güneş, Yasin},
title = {Epicardial adipose tissue (EAT) thickness on non-gated chest CT as an alternative to EAT volume on cardiac CT},
journal = {Acta Radiologica},
year = {2024},
doi = {10.1177/02841851241246626}
}