Deep learning-accelerated T2-weighted imaging versus conventional T2-weighted imaging in the female pelvic cavity: image quality and diagnostic performance
Acta Radiologica · 2024
DOI: 10.1177/02841851241228192 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Radiologica, 2024. Verfasst von Hokun Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seoul St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Pelvis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
Background
The deep learning (DL)-based reconstruction algorithm reduces noise in magnetic resonance imaging (MRI), thereby enabling faster MRI acquisition.
Purpose
To compare the image quality and diagnostic performance of conventional turbo spin-echo (TSE) T2-weighted (T2W) imaging with DL-accelerated sagittal T2W imaging in the female pelvic cavity.
Methods
This study evaluated 149 consecutive female pelvic MRI examinations, including conventional T2W imaging with TSE (acquisition time = 2:59) and DL-accelerated T2W imaging with breath hold (DL-BH) (1:05 [0:14 × 3 breath-holds]) in the sagittal plane. In 294 randomly ordered sagittal T2W images, two radiologists independently assessed image quality (sharpness, subjective noise, artifacts, and overall image quality), made a diagnosis for uterine leiomyomas, and scored diagnostic confidence. For the uterus and piriformis muscle, quantitative imaging analysis was also performed. Wilcoxon signed rank tests were used to compare the two sets of T2W images.
Results
In the qualitative analysis, DL-BH showed similar or significantly higher scores for all features than conventional T2W imaging ( P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Seoul St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
- Department of Radiology, Eunpyeong St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
- Research Collaboration, Siemens Healthineers Ltd, Seoul, Republic of Korea.
- Digital Technology & Innovation, Siemens Medical Solutions USA, Inc., Princeton, NJ, USA.
- MR Applications Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany.
ORCID-Profile: Moon Hyung Choi
Zitieren
APA
Kim, H., Choi, M. H., Lee, Y. J., Han, D., Mostapha, M., & Nickel, D. (2024). Deep learning-accelerated T2-weighted imaging versus conventional T2-weighted imaging in the female pelvic cavity: image quality and diagnostic performance. Acta Radiologica. https://doi.org/10.1177/02841851241228192
Vancouver
Kim H, Choi MH, Lee YJ, Han D, Mostapha M, Nickel D. Deep learning-accelerated T2-weighted imaging versus conventional T2-weighted imaging in the female pelvic cavity: image quality and diagnostic performance. Acta Radiologica. 2024. doi:10.1177/02841851241228192
BibTeX
@article{Kim2024,
author = {Kim, Hokun and Choi, Moon Hyung and Lee, Young Joon and Han, Dongyeob and Mostapha, Mahmoud and Nickel, Dominik},
title = {Deep learning-accelerated T2-weighted imaging versus conventional T2-weighted imaging in the female pelvic cavity: image quality and diagnostic performance},
journal = {Acta Radiologica},
year = {2024},
doi = {10.1177/02841851241228192}
}
EUVIMED