EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Predicting walking capacity, walking performance, and life space mobility using socket comfort in lower-limb prosthesis users

Gordon Tao iD, Jayden Singh, Malena Rapaport, Michael Payne, William C Miller iD

Clinical Rehabilitation · 2025

DOI: 10.1177/02692155251374927 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Clinical Rehabilitation, 2025. Verfasst von Gordon Tao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Rehabilitation Research Program, Centre for Aging SMART at Vancouver Coastal Health, Vancouver, BC, Canada. Hauptthemen laut MEDLINE: Artificial Limbs, Walking, Amputees. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine if socket comfort predicts walking capacity, walking performance, and life-space mobility.

Design

Observational exploratory study involving a secondary cross-sectional analysis using multiple regression of data collected from an exercise intervention trial.

Setting

Laboratory setting for clinical assessments; community setting for walking performance.

Participants

Community-dwelling lower-limb prosthesis users over 50 years old ( n = 72). Main measures Socket Comfort Score, 2-Minute Walk Test, step count, Life Space Assessment, and control variables including demographics, Short Physical Performance Battery, Four Square Step Test, and Walking While Talking.

Results

Regression modeling showed Socket Comfort Score as a statistically significant predictor of 2-Minute Walk Test ( B = 6.9 m, 95% CI [2.7, 11.1] m) alongside amputation level, Walking While Talking test, and Short Physical Performance Battery (greatest contribution to the model); the model accounted for 61% of the variance. Socket Comfort Score was not a statistically significant predictor of step count. Socket Comfort Score was the only statistically significant predictor of Life Space Assessment ( B = 4.9, 95% CI [1.1, 8.8]); the model accounted for 12% of the variance.

Conclusions

Socket comfort played a notable role in predicting walking capacity and life space mobility, but not in walking performance. Improving lower extremity function may have greater impact on walking overall. While this study provides context regarding socket comfort that clinicians may consider when planning holistic prosthetic rehabilitation, mixed findings in the literature suggest that further research on how socket comfort relates to walking outcomes in the community is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial LimbsWalkingAmputeesHumansMaleFemaleCross-Sectional StudiesMiddle AgedAgedWalk TestProsthesis DesignLower ExtremityProsthesis Fitting

Stichwörter der Autor:innen

Socket comfortlife space mobilitywalking capacitywalking performance

Autor:innen und Institutionen

  • Rehabilitation Research Program, Centre for Aging SMART at Vancouver Coastal Health, Vancouver, BC, Canada.
  • Department of Occupational Science and Occupational Therapy, The University of British Columbia, Vancouver, BC, Canada.
  • Graduate Program in Rehabilitation Sciences, Faculty of Medicine, The University of British Columbia, Vancouver, BC, Canada.
  • School of Kinesiology, Faculty of Education, The University of British Columbia, Vancouver, BC, Canada.
  • Prosthetics & Orthotics Program, British Columbia Institute of Technology, Burnaby, British Columbia, Canada.
  • Department of Physical Medicine & Rehabilitation, Schulich School of Medicine & Dentistry, University of Western Ontario, London, ON, Canada.

ORCID-Profile: Gordon Tao, William C Miller

Förderung

  • Canadian Institutes of Health Research

Zitieren

APA

Tao, G., Singh, J., Rapaport, M., Payne, M., & Miller, W. C. (2025). Predicting walking capacity, walking performance, and life space mobility using socket comfort in lower-limb prosthesis users. Clinical Rehabilitation. https://doi.org/10.1177/02692155251374927

Vancouver

Tao G, Singh J, Rapaport M, Payne M, Miller WC. Predicting walking capacity, walking performance, and life space mobility using socket comfort in lower-limb prosthesis users. Clinical Rehabilitation. 2025. doi:10.1177/02692155251374927

BibTeX
@article{Tao2025,
  author = {Tao, Gordon and Singh, Jayden and Rapaport, Malena and Payne, Michael and Miller, William C},
  title = {Predicting walking capacity, walking performance, and life space mobility using socket comfort in lower-limb prosthesis users},
  journal = {Clinical Rehabilitation},
  year = {2025},
  doi = {10.1177/02692155251374927}
}
Kostenlos starten →