EUVIMEDEUVIMED entdecken
Crossref

Computer-assisted vacuum thrombectomy using lightning 12 and lightning flash 16 in acute proximal lower extremity deep vein thrombosis

Mauricio Gonzalez-Urquijo iD, Jose Francisco Vargas iD, Leopoldo Marine, Michel Bergoeing, Sebastian Sepulveda, Francisco Valdes iD

Phlebology: The Journal of Venous Disease · 2025

DOI: 10.1177/02683555251404147 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Phlebology: The Journal of Venous Disease, 2025. Verfasst von Mauricio Gonzalez-Urquijo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Tecnologico de Monterrey, School of Medicine and Health Sciences, Monterrey, Mexico. Hauptthemen laut MEDLINE: Venous Thrombosis, Thrombectomy, Lower Extremity, Surgery, Computer-Assisted. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To report a single-center experience using the Lightning 12 and Lightning Flash 16 computer-assisted vacuum thrombectomy (CAVT) Indigo System devices for acute proximal lower extremity deep vein thrombosis (DVT).

Methods

A retrospective review was conducted of all consecutive patients treated with CAVT for acute (70% thrombus removal on final completion venography, assessed by at least two different operators.

Results

Twenty-four patients (median age 55.5 years; 58.3% female) with 29 affected limbs were included. Classical May-Thurner syndrome was present in 37.5%. Thrombosis involved the left iliofemoral segment in 44.8%, right iliofemoral in 31.0%, isolated common iliac vein in 6.8%, and inferior vena cava extension in 17.2%. Devices used included Lightning 12 (25.0%) and Lightning Flash 16 (75.0%). Iliac vein stents were placed in 82.8% of limbs. Median operative time was 120 min, blood loss 750 cc, and hospital stay 2 days. No intraoperative complications occurred. Two non-procedure-related deaths occurred within 30 days. Median follow-up was 9 months; three additional late deaths were unrelated to the procedure. The median Villalta score was 1, and VCSS was 1. No significant outcome differences were observed between the two device types.

Conclusion

The CAVT Indigo System appears to be a safe and effective treatment option for acute proximal lower extremity DVT, demonstrating high technical success and low complication rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Venous ThrombosisThrombectomyLower ExtremitySurgery, Computer-AssistedHumansFemaleMiddle AgedRetrospective StudiesMaleAgedAdultAcute DiseaseVacuumIliac Vein

Stichwörter der Autor:innen

computer-assisted vacuum thrombectomy (CAVT)deep vein thrombosis (DVT)iliofemoral thrombosismechanical thrombectomypenumbra

Autor:innen und Institutionen

  • Tecnologico de Monterrey, School of Medicine and Health Sciences, Monterrey, Mexico.
  • Departamento de Cirugía Vascular y Endovascular, Escuela de Medicina, Pontificia Universidad Católica de Chile, Santiago, Chile.

ORCID-Profile: Mauricio Gonzalez-Urquijo, Jose Francisco Vargas, Francisco Valdes

Zitieren

APA

Gonzalez-Urquijo, M., Vargas, J. F., Marine, L., Bergoeing, M., Sepulveda, S., & Valdes, F. (2025). Computer-assisted vacuum thrombectomy using lightning 12 and lightning flash 16 in acute proximal lower extremity deep vein thrombosis. Phlebology: The Journal of Venous Disease. https://doi.org/10.1177/02683555251404147

Vancouver

Gonzalez-Urquijo M, Vargas JF, Marine L, Bergoeing M, Sepulveda S, Valdes F. Computer-assisted vacuum thrombectomy using lightning 12 and lightning flash 16 in acute proximal lower extremity deep vein thrombosis. Phlebology: The Journal of Venous Disease. 2025. doi:10.1177/02683555251404147

BibTeX
@article{GonzalezUrquijo2025,
  author = {Gonzalez-Urquijo, Mauricio and Vargas, Jose Francisco and Marine, Leopoldo and Bergoeing, Michel and Sepulveda, Sebastian and Valdes, Francisco},
  title = {Computer-assisted vacuum thrombectomy using lightning 12 and lightning flash 16 in acute proximal lower extremity deep vein thrombosis},
  journal = {Phlebology: The Journal of Venous Disease},
  year = {2025},
  doi = {10.1177/02683555251404147}
}
Kostenlos starten →