Three-year follow-up analysis of automated microfoam preparation system for great saphenous vein incompetence and varicose veins sclerotherapy treatment
Phlebology: The Journal of Venous Disease · 2024
DOI: 10.1177/02683555241250226 ↗Kurz gefasst
Fachartikel in der Zeitschrift Phlebology: The Journal of Venous Disease, 2024. Verfasst von Giovanni Alongi und 2 weiteren Autor:innen. Beteiligte Einrichtung: AngioCor Clinic, Palermo, Italy. Hauptthemen laut MEDLINE: Varicose Veins, Sclerotherapy, Saphenous Vein, Venous Insufficiency. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
Background
To describe the treatment of patients with great saphenous vein (GSV) incompetence and varicose veins (VVs), utilizing an Automated Microfoam Preparation System (AMPS, Varixio ® , VB Devices, Barcelona, Spain).
Methods
Adults between January and June 2021 were included. The AMPS system was used for foam preparation. Sclerotherapy treatment followed international recommendations. The primary endpoint was GSV closure rate after 36 months.
Results
164 patients were enrolled. During the 7-day follow-up period, all GSVs showed complete closure, which was maintained at the 1-year mark. No major complications were reported. A cumulative complete GSV recanalization rate of 6.1% and a partial recanalization rate of 26.8% after 36 months were noted. Some patients (9.7%) required additional treatment. A higher BMI was associated with complete recanalization.
Conclusion
The AMPS offers an easy-to-use and standardized procedure, potentially enhancing treatment outcomes if compared with manual preparation. Caution is advised when treating obese patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- AngioCor Clinic, Palermo, Italy.
- Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy.
- Vein Clinic Brescia, Brescia, Italy.
ORCID-Profile: Daniele Bissacco, Edoardo Cervi
Zitieren
APA
Alongi, G., Bissacco, D., & Cervi, E. (2024). Three-year follow-up analysis of automated microfoam preparation system for great saphenous vein incompetence and varicose veins sclerotherapy treatment. Phlebology: The Journal of Venous Disease. https://doi.org/10.1177/02683555241250226
Vancouver
Alongi G, Bissacco D, Cervi E. Three-year follow-up analysis of automated microfoam preparation system for great saphenous vein incompetence and varicose veins sclerotherapy treatment. Phlebology: The Journal of Venous Disease. 2024. doi:10.1177/02683555241250226
BibTeX
@article{Alongi2024,
author = {Alongi, Giovanni and Bissacco, Daniele and Cervi, Edoardo},
title = {Three-year follow-up analysis of automated microfoam preparation system for great saphenous vein incompetence and varicose veins sclerotherapy treatment},
journal = {Phlebology: The Journal of Venous Disease},
year = {2024},
doi = {10.1177/02683555241250226}
}
EUVIMED