Serum aquaporin-1 increases with heart failure and aortic valve surgery with cardiopulmonary bypass
Perfusion · 10.08.2026
DOI: 10.1177/02676591261476511 ↗Kurz gefasst
Fachartikel in der Zeitschrift Perfusion, online erschienen am 10.08.2026. Verfasst von María Teresa Politi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Facultad de Ciencias Médicas, Departamento de Ciencias Fisiológicas, Laboratorio de Biomembranas, Universidad de Buenos Aires, Buenos Aires, Argentin…. Die Arbeit nennt 17 Literaturangaben. Gefördert von: National Agency for Scientific and Technological Promotion, Subsidio Florencio Fiorini para la Investigación en Ciencias Biomédicas Año 2020.
Themen: Herzinsuffizienz
Abstract (Originalsprache)
Introduction
Serum aquaporin-1 increases with inflammation and edema. However, its role as a cardiovascular biomarker remains unexplored. The goal of this study is to evaluate serum aquaporin-1 concentrations across two distinct clinical settings characterized by myocardial stress and congestion: acute heart failure and surgical aortic valve replacement with cardiopulmonary bypass.
Methods
This observational study included healthy volunteers ( n = 8), acute heart failure patients ( n = 11), and surgical aortic valve replacement patients ( n = 11). Serum aquaporin-1 was measured using ELISA. Myocardial biopsies were obtained for aquaporin-1 and aquaporin-4 protein quantification before and after cardiopulmonary bypass in six patients.
Results
Serum aquaporin-1 levels were significantly higher in acute heart failure (3,921 ± 1,396 pg/mL; p = 0.0006) and surgical aortic valve replacement patients (3,318 ± 1,394 pg/mL; p = 0.0070) compared to healthy volunteers (1,755 ± 807 pg/mL). These differences remained significant after adjusting for sex and age. All patients with low cardiac output had serum aquaporin-1 concentrations in the upper half of their group distribution. Serum aquaporin-1 correlated moderately with B-type natriuretic peptide (r = 0.40; p = 0.0265), C-reactive protein (r = 0.42; p = 0.0203), and erythrocyte sedimentation rate (r = 0.45; p = 0.0117). Following cardiopulmonary bypass, myocardial aquaporin-1 increased (73%; p = 0.0310), while aquaporin-4 decreased (53%; p = 0.0440), with a strong but non-significant correlation between cardiac and serum aquaporin-1 changes.
Conclusion
Serum aquaporin-1 levels are elevated in acute heart failure and post-surgical aortic valve replacement patients, particularly in those with low cardiac output.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Facultad de Ciencias Médicas, Departamento de Ciencias Fisiológicas, Laboratorio de Biomembranas, Universidad de Buenos Aires, Buenos Aires, Argentina.
- Instituto de Fisiología y Biofísica Bernardo Houssay (IFIBIO Houssay), CONICET - Universidad de Buenos Aires, Buenos Aires, Argentina.
- Department of Cardiology, Sanatorio de la Trinidad Mitre, Buenos Aires, Argentina.
ORCID-Profile: María Teresa Politi
Förderung
- National Agency for Scientific and Technological Promotion
- Subsidio Florencio Fiorini para la Investigación en Ciencias Biomédicas Año 2020
Zitieren
APA
Politi, M. T., Blanco, M., Fonseca, S. R., Ferreyra, R., Bortman, G., Piazza, A., Di Giusto, G., & Capurro, C. (2026). Serum aquaporin-1 increases with heart failure and aortic valve surgery with cardiopulmonary bypass. Perfusion. https://doi.org/10.1177/02676591261476511
Vancouver
Politi MT, Blanco M, Fonseca SR, Ferreyra R, Bortman G, Piazza A, et al. Serum aquaporin-1 increases with heart failure and aortic valve surgery with cardiopulmonary bypass. Perfusion. 2026. doi:10.1177/02676591261476511
BibTeX
@article{Politi2026,
author = {Politi, María Teresa and Blanco, Mailén and Fonseca, Sebastián Raúl and Ferreyra, Raúl and Bortman, Guillermo and Piazza, Antonio and Di Giusto, Gisela and Capurro, Claudia},
title = {Serum aquaporin-1 increases with heart failure and aortic valve surgery with cardiopulmonary bypass},
journal = {Perfusion},
year = {2026},
doi = {10.1177/02676591261476511}
}
EUVIMED