Innovative use of quality indicators during cardiopulmonary bypass: a goal directed perfusion strategy using real-time area under the threshold analysis
Perfusion · 22.07.2026
DOI: 10.1177/02676591261471110 ↗Kurz gefasst
Fachartikel in der Zeitschrift Perfusion, online erschienen am 22.07.2026. Verfasst von Marloes van Hoeven und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Extracorporeal Circulation, Catharina Hospital, Eindhoven, The Netherlands. Die Arbeit nennt 19 Literaturangaben. Gefördert von: TKI-HTSM Medtech, Sorin Group Italy S.r.l..
Abstract (Originalsprache)
This study aims to assess current quality indicators and determine the added value of total area under the threshold (TAUT) and largest area under the threshold (LAUT) for risk factors associated with post-cardiosurgical acute kidney injury (AKI) in a large patient population. This approach may offer insights to further reduce the incidence of AKI.
Methods
This is a retrospective single center study of procedures from January 1st 2019 to August 31st 2023. The final cohort included 3086 patients who underwent on-pump cardiothoracic surgery procedures at a temperature ≥ 34°C. This study particularly focused of three risk factors for AKI, namely, the oxygen delivery (DO 2 i), venous saturation (SvO 2 ) and mean arterial pressure (MAP).
Results
The TAUT-DO 2 i 300 (threshold value 300 mL/min/m 2 ), as well as the TAUT-SvO 2 70 (threshold value 70%) were significantly larger in the group of patients who developed AKI (P < 0.001). The TAUT-MAP 60 (threshold value 60 mmHg) was significantly different between AKI and non-AKI groups during CPB, but they were significantly larger for the AKI group during the first 6 h at the ICU (P < 0.001).
Conclusion
The findings indicate that increased cumulative AUT-DO 2 i 300 exposure may be linked to a higher risk of AKI, supporting the potential role of AUT-based monitoring in guiding intraoperative management during on-pump cardiac surgery.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Extracorporeal Circulation, Catharina Hospital, Eindhoven, The Netherlands.
- Department of Electrical Engineering, Technical University, Eindhoven, The Netherlands.
- Department of Extracorporeal Circulation, Medical Spectrum Twente, Enschede, The Netherlands.
- Department of Anesthesiology, Catharina Hospital, Eindhoven, The Netherlands.
Förderung
- TKI-HTSM Medtech
- Sorin Group Italy S.r.l.
Zitieren
APA
van Hoeven, M., Gensen, C., Overdevest, E., Gerritse, M., Turco, S., & Bouwman, A. (2026). Innovative use of quality indicators during cardiopulmonary bypass: a goal directed perfusion strategy using real-time area under the threshold analysis. Perfusion. https://doi.org/10.1177/02676591261471110
Vancouver
van Hoeven M, Gensen C, Overdevest E, Gerritse M, Turco S, Bouwman A. Innovative use of quality indicators during cardiopulmonary bypass: a goal directed perfusion strategy using real-time area under the threshold analysis. Perfusion. 2026. doi:10.1177/02676591261471110
BibTeX
@article{vanHoeven2026,
author = {van Hoeven, Marloes and Gensen, Carmen and Overdevest, Eddy and Gerritse, Matthijs and Turco, Simona and Bouwman, Arthur},
title = {Innovative use of quality indicators during cardiopulmonary bypass: a goal directed perfusion strategy using real-time area under the threshold analysis},
journal = {Perfusion},
year = {2026},
doi = {10.1177/02676591261471110}
}
EUVIMED