Fachartikel in der Zeitschrift Perfusion, 2025. Verfasst von Liangshan Wang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Center for Cardiac Intensive Care, Beijing Anzhen Hospital, Capital Medical University, Beijing, People's Republic of China. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Extracorporeal Membrane Oxygenation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: Beijing Municipal Natural Science Foundation, National Natural Science Foundation of China, Young Elite Scientists Sponsorship Program by CAST.
Abstract (Originalsprache)
Objective
Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) can provide temporary circulatory and respiratory support allowing hemodynamic stabilization during high-risk transcatheter aortic valve replacement (TAVR). However, the optimal timing of VA-ECMO use in high-risk TAVR remains controversial. We aimed to report our experience using a novel standby ECMO strategy during high-risk TAVR.
Methods
We retrospectively evaluated consecutive patients who received high-risk TAVR with standby ECMO between March 1,2023 and March 1,2024 at the Beijing Anzhen Hospital. Small, 5F or 6F sheaths were placed in ipsilateral femoral vein and artery before TAVR procedures. The primary outcome of this study was survival to hospital discharge with good neurological recovery defined as cerebral performance category (CPC) 1-2.
Results
A total of 24 patients undergoing high-risk TAVR with standby ECMO were included. Six (25.0%) of the 24 patients with standby ECMO suffered from cardiogenic shock or cardiac arrest and required emergency VA-ECMO institution. The median (IQR) cannulation time was 8 (6–11) minutes, and the median (IQR) ECMO duration was 35 (24–48) hours. All of the 24 patients underwent successful TAVR procedures and survival to hospital discharge with CPC1-2.
Conclusions
Standby ECMO with preset femoral vascular sheaths was feasible and effective for refractory cardiogenic shock and cardiac arrest during high-risk TAVR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Cardiac Intensive Care, Beijing Anzhen Hospital, Capital Medical University, Beijing, People's Republic of China.
ORCID-Profile: Liangshan Wang, Zhongtao Du
Förderung
- Beijing Municipal Natural Science Foundation
- National Natural Science Foundation of China
- Young Elite Scientists Sponsorship Program by CAST
- Beijing Nova Program
- Beijing Hospitals Authority Youth Programme
- National Key Research and Development Program of China
Zitieren
APA
Wang, L., Wang, Y., Fu, H., Meng, X., Li, C., Jiang, C., Guo, D., Xu, B., Wang, P., Li, Y., Jia, M., Wang, H., & Du, Z. (2025). Feasibility of standby ECMO with preset femoral vascular sheaths for high-risk transcatheter aortic valve replacement. Perfusion. https://doi.org/10.1177/02676591241263285
Vancouver
Wang L, Wang Y, Fu H, Meng X, Li C, Jiang C, et al. Feasibility of standby ECMO with preset femoral vascular sheaths for high-risk transcatheter aortic valve replacement. Perfusion. 2025. doi:10.1177/02676591241263285
BibTeX
@article{Wang2025,
author = {Wang, Liangshan and Wang, Yan and Fu, Hongfu and Meng, Xin and Li, Chenglong and Jiang, Chunjing and Guo, Dong and Xu, Bo and Wang, Pengcheng and Li, Yu and Jia, Ming and Wang, Hong and Du, Zhongtao},
title = {Feasibility of standby ECMO with preset femoral vascular sheaths for high-risk transcatheter aortic valve replacement},
journal = {Perfusion},
year = {2025},
doi = {10.1177/02676591241263285}
}
EUVIMED