Heparin consumption and inflammatory response according to the coating of cardiopulmonary bypass circuits in cardiac surgery: A retrospective analysis
Perfusion · 2024-11 · 39 (8) · 1531-1537
DOI: 10.1177/02676591231215282 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Perfusion, online erschienen am 09.11.2023. Verfasst von Laurent Mathieu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Haut-Lévêque Hospital, Surgical Centre, Bordeaux University Hospital, Pessac, France. Hauptthemen laut MEDLINE: Cardiopulmonary Bypass, Heparin, Inflammation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Introduction
There are several types of surface treatments (coatings) aimed at improving the biocompatibility of cardiopulmonary bypass (CPB) circuit. Some coatings appear to require higher doses of heparin to maintain anticoagulation goals, and some of them might induce postoperative coagulopathy. In this study, we compared the amount of heparin required, postoperative bleeding, and inflammatory response according to three types of coatings.
Method
We retrospectively included 300 consecutive adult patients who underwent cardiac surgery with CPB and received one of three coatings (Phisio®, Trillium®, and Xcoating™). Our primary objective was to compare, according to coating, the amount of heparin required to maintain an ACT > 400s during CPB. Our secondary objectives were to compare postoperative bleeding for 48 h and CRP rate.
Results
Baseline characteristics were comparable between groups except for age and preoperative CRP. We did not find a significant difference between the 3 coatings regarding the amount of heparin reinjected. However, we found less postoperative bleeding with the Xcoating™ circuit compared to the Phisio® circuit (−149 mL [−289; −26.5]; p = 0.02) and a lower elevation of CRP with the Phisio® circuit (2.8 times higher than preoperative CRP) compared to Trillium® (4.9 times higher) and Xcoating™ (6.4 times higher); p < 10 –3 .
Conclusion
The choice of coating did not influence the amount of heparin required during CPB; however, the post-CPB inflammatory syndrome may be impacted by this choice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Haut-Lévêque Hospital, Surgical Centre, Bordeaux University Hospital, Pessac, France.
- Department of Cardiovascular Anesthesia and Critical Care, Haut-Lévêque Hospital, Bordeaux University Hospital, Bordeaux, France.
- Univ. Bordeaux, INSERM, Biologie des maladies cardiovasculaires, U1034, F-33600 Pessac, France.
- Research and Innovation Unit in Healthcare and Humanities (URISH), Bordeaux-University Hospital, Bordeaux, France.
ORCID-Profile: Laurent Mathieu, Alexandre Ouattara
Zitieren
APA
Mathieu, L., Beurton, A., Rougier, N., Flambard, M., Germain, C., Pernot, M., & Ouattara, A. (2024). Heparin consumption and inflammatory response according to the coating of cardiopulmonary bypass circuits in cardiac surgery: A retrospective analysis. Perfusion, 39(8), 1531-1537. https://doi.org/10.1177/02676591231215282
Vancouver
Mathieu L, Beurton A, Rougier N, Flambard M, Germain C, Pernot M, et al. Heparin consumption and inflammatory response according to the coating of cardiopulmonary bypass circuits in cardiac surgery: A retrospective analysis. Perfusion. 2024;39(8):1531-1537. doi:10.1177/02676591231215282
BibTeX
@article{Mathieu2024,
author = {Mathieu, Laurent and Beurton, Antoine and Rougier, Nicolas and Flambard, Maude and Germain, Christine and Pernot, Mathieu and Ouattara, Alexandre},
title = {Heparin consumption and inflammatory response according to the coating of cardiopulmonary bypass circuits in cardiac surgery: A retrospective analysis},
journal = {Perfusion},
year = {2024},
volume = {39},
number = {8},
pages = {1531--1537},
doi = {10.1177/02676591231215282}
}
EUVIMED