Fachartikel in der Zeitschrift Asian Cardiovascular and Thoracic Annals, online erschienen am 31.03.2026. Verfasst von Ahmad Walid Izzat und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Damascus University Faculty of Medicine, Damascus, Syria. Hauptthemen laut MEDLINE: Suture Techniques, Blood Vessel Prosthesis Implantation, Blood Loss, Surgical, Aortic Dissection. Die Arbeit nennt 7 Literaturangaben.
Abstract (Originalsprache)
Background
Securing hemostasis at graft-to-aorta anastomoses represents a challenging feature of the surgical management of aortic pathologies, and can impact postoperative morbidity and mortality. A new refined suturing technique was developed to address this challenge.
Methods
A Dacron tube graft of appropriate size is secured within the aortic lumen using a horizontal 4-0 Prolene U-stay suture, and its two arms are used to complete the anastomosis continuously. With every bite, the needle is driven horizontally across an outer circumferential felt strip and aorta (out-in), through the graft at a 2–3-mm distance from its edge (out-in), back through the graft at a 7–8-mm distance from its edge (in-out), and finally bridging over the aortic edge back to its outer aspect without piercing the aortic wall. The two running sutures are firmly tightened and knotted, and Bioglue is applied.
Results
The described technique was used in 175 patients who underwent ascending aortic replacement for aortic aneurysm or acute dissection. We have found its application to be associated with improved hemostasis and reduced intraoperative and postoperative blood loss. Additional sutures were rarely needed for hemostasis at suture lines, and there were no incidents of false aneurysm formation at anastomosis lines on long-term follow-up.
Conclusions
The described technique is associated with improved hemostasis, reduced blood loss, and decreased operating time, ultimately bringing significant benefits to patients undergoing surgical management of aortic pathologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Surgery, Damascus University Faculty of Medicine, Damascus, Syria.
ORCID-Profile: Ahmad Walid Izzat, Mohammad Bashar Izzat
Zitieren
APA
Izzat, A. W., & Izzat, M. B. (2026). Refined suturing technique for graft-to-aorta anastomoses. Asian Cardiovascular and Thoracic Annals, 34(4), 400-403. https://doi.org/10.1177/02184923261439235
Vancouver
Izzat AW, Izzat MB. Refined suturing technique for graft-to-aorta anastomoses. Asian Cardiovascular and Thoracic Annals. 2026;34(4):400-403. doi:10.1177/02184923261439235
BibTeX
@article{Izzat2026,
author = {Izzat, Ahmad Walid and Izzat, Mohammad Bashar},
title = {Refined suturing technique for graft-to-aorta anastomoses},
journal = {Asian Cardiovascular and Thoracic Annals},
year = {2026},
volume = {34},
number = {4},
pages = {400--403},
doi = {10.1177/02184923261439235}
}
EUVIMED