Continuous Glucose Monitoring System After Coronary Artery Bypass Graft Surgery: A Feasibility Study
Asian Cardiovascular and Thoracic Annals · 2024
DOI: 10.1177/02184923241240035 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Asian Cardiovascular and Thoracic Annals, 2024. Verfasst von Tiziano Torre und 8 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Surgery Department, Cardiocentro Ticino Institute, Lugano, Switzerland. Hauptthemen laut MEDLINE: Blood Glucose, Coronary Artery Bypass, Feasibility Studies, Biomarkers. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 13 Literaturangaben.
Abstract (Originalsprache)
Background
Blood glucose level variability has been associated with increased risk of complication in the postoperative setting of cardiovascular surgery. Although interesting for optimization of blood glucose management in this context, continuous blood glucose (CBG) devices can have a limited reliability in this context, in particular because of the use of paracetamol. The aim of this study was to evaluate the reliability of Dexcom G6®, a recently developed continuous glucose monitoring device.
Methods
We performed a prospective, observational, non-randomized, single-centre study comparing Dexcom G6® CBG level monitoring with the standard methods routinely used in this context. The standard blood glucose values were paired to the time corresponding values measured with Dexcom G6®. Agreement between the two methods and potential correlation in case of paracetamol use were calculated.
Results
From May 2020 to August 2021, 36 out of 206 patients operated for isolated coronary artery bypass grafting were enrolled; 673 paired blood glucose level were analyzed. Global agreement (ρc) was 0.85 (95% C.I.: 0.84–0.86), intensive care unit agreement was 0.78 (95%C.I.: 0.74–0.82) and ward agreement was 0.91 (95%C.I.: 0.89–0.93). In the diabetic population, it was 0.87 (95%C.I.: 0.85–0.90). When paracetamol was used, the difference was 0.02 mmol/l (95%C.I.: 0.29–0.33).
Conclusions
Dexcom G6 ® provides good blood glucose level accuracy in the postoperative context of cardiac surgery compared to the standard methods of measurements. The results are particularly reliable in the ward where the need for repeated capillary glucose measurements implies patient discomfort and time-consuming manipulations for the nursing staff.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Cardiac Surgery Department, Cardiocentro Ticino Institute, Lugano, Switzerland.
- Anestesiology Department, Cardiocentro Ticino Institute, Lugano, Switzerland.
- Service of Clinical Epidemiology & Biometry, IRCCS Fondazione Policlinico San Matteo, Pavia, Italy.
ORCID-Profile: Francesca Toto
Zitieren
APA
Torre, T., Schlotterbeck, H., Ferraro, F., Klersy, C., Surace, G., Toto, F., Pozzoli, A., Ferrari, E., & Demertzis, S. (2024). Continuous Glucose Monitoring System After Coronary Artery Bypass Graft Surgery: A Feasibility Study. Asian Cardiovascular and Thoracic Annals. https://doi.org/10.1177/02184923241240035
Vancouver
Torre T, Schlotterbeck H, Ferraro F, Klersy C, Surace G, Toto F, et al. Continuous Glucose Monitoring System After Coronary Artery Bypass Graft Surgery: A Feasibility Study. Asian Cardiovascular and Thoracic Annals. 2024. doi:10.1177/02184923241240035
BibTeX
@article{Torre2024,
author = {Torre, Tiziano and Schlotterbeck, Hervé and Ferraro, Francesco and Klersy, Catherine and Surace, Giuseppina and Toto, Francesca and Pozzoli, Alberto and Ferrari, Enrico and Demertzis, Stefanos},
title = {Continuous Glucose Monitoring System After Coronary Artery Bypass Graft Surgery: A Feasibility Study},
journal = {Asian Cardiovascular and Thoracic Annals},
year = {2024},
doi = {10.1177/02184923241240035}
}
EUVIMED