EUVIMEDEUVIMED entdecken
Crossref

A High-Resolution and High-Contrast Beamforming Algorithm Based on Null Subtraction Imaging Applied to Synthetic Transmit Aperture

Roya Paridar iD, Babak Mohammadzadeh Asl iD

Ultrasonic Imaging · 2026

DOI: 10.1177/01617346251384583 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultrasonic Imaging, 2026. Verfasst von Roya Paridar und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Tarbiat Modares University, Tehran, Islamic Republic of Iran. Hauptthemen laut MEDLINE: Algorithms, Image Processing, Computer-Assisted, Subtraction Technique, Image Enhancement. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In medical ultrasound imaging, achieving high-quality reconstructed images while avoiding a huge computational burden is an important challenge. The Null subtraction imaging (NSI) algorithm results in a high-resolution reconstructed image. However, this method is not successful in recovering the background speckle information. In this paper, a novel algorithm, known as NSI-based generalized coherence factor (GCF)-along with delay-and-sum (DAS), which is abbreviated as NSG-DAS, is developed to overcome this limitation. In the proposed method, by using a hybrid technique, the desired resolution and effective noise suppression of the NSI algorithm, as well as the background speckle information of the conventional DAS beamformer are recovered simultaneously. More precisely, by using the GCF method, a new weighing factor is introduced that enhances the coherent regions of the image and suppresses the off-axis signals. Evaluations prove the favorable performance of the suggested technique; in particular, by using the proposed NSG-DAS method, a resolution comparable to the NSI algorithm is achieved for the geabr0 dataset, which is improved by about 42% compared to DAS. Also, the contrast evaluation parameter of the suggested technique is comparable to the DAS algorithm and is improved by about 63% compared to the NSI method. This indicates the ability of the suggested technique to improve either resolution or contrast simultaneously.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsImage Processing, Computer-AssistedSubtraction TechniqueImage EnhancementUltrasonographyPhantoms, ImagingHumans

Stichwörter der Autor:innen

high resolutionnull subtraction imagingspeckle preservationsynthetic transmit apertureultrasound

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Tarbiat Modares University, Tehran, Islamic Republic of Iran.

ORCID-Profile: Roya Paridar, Babak Mohammadzadeh Asl

Zitieren

APA

Paridar, R., & Mohammadzadeh Asl, B. (2026). A High-Resolution and High-Contrast Beamforming Algorithm Based on Null Subtraction Imaging Applied to Synthetic Transmit Aperture. Ultrasonic Imaging. https://doi.org/10.1177/01617346251384583

Vancouver

Paridar R, Mohammadzadeh Asl B. A High-Resolution and High-Contrast Beamforming Algorithm Based on Null Subtraction Imaging Applied to Synthetic Transmit Aperture. Ultrasonic Imaging. 2026. doi:10.1177/01617346251384583

BibTeX
@article{Paridar2026,
  author = {Paridar, Roya and Mohammadzadeh Asl, Babak},
  title = {A High-Resolution and High-Contrast Beamforming Algorithm Based on Null Subtraction Imaging Applied to Synthetic Transmit Aperture},
  journal = {Ultrasonic Imaging},
  year = {2026},
  doi = {10.1177/01617346251384583}
}
Kostenlos starten →