Development of a Polymer Ultrasound Contrast Agent Incorporating Nested Carbon Nanodots
Ultrasonic Imaging · 2025
DOI: 10.1177/01617346241279112 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasonic Imaging, 2025. Verfasst von Matthew A Shirley und 5 weiteren Autor:innen. Beteiligte Einrichtung: Drexel University School of Biomedical Engineering Science and Health Systems, Philadelphia, PA, USA. Hauptthemen laut MEDLINE: Contrast Media, Microbubbles, Ultrasonography, Quantum Dots. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 64 Literaturangaben. Gefördert von: National Science Foundation Graduate Research Fellowship Program.
Abstract (Originalsprache)
Polymer microbubbles have garnered broad interest as potential theranostic agents. However, the capabilities of polymer MBs can be greatly enhanced, particularly regarding the imaging performance and functional versatility of the platform. This study investigates integrating fluorescent carbon nanodots within polylactic acid (PLA) microbubbles. First, the formulations are characterized by their size, microbubble counts, zeta potential, and resonance frequency. Then, the fluorescence capabilities, nanoparticle loading, and acoustic capabilities are examined. Unmodified (U-), carboxylated (C-), and aminated graphene quantum dots (A-GQDs) were separately suspended and synthesized at a 2% w/w ratio with PLA in the organic phase of the water/oil/water double emulsion process. The new microbubbles were characterized using an AccuSizer, Zetasizer, scanning electron microscopy, fluorescence microscopy and fluorimetry, a custom-built acoustic setup, and clinical ultrasound. The GQD microbubbles were sized between 1.4 and 1.9 µm (U = 1.90, C = 1.44, A = 1.72, Unloaded = 2.02 µm). The U-GQD microbubble exhibited a higher bubble concentration/mg PLA ( p < .05) and the A-GQD microbubbles exhibited the greatest shift in zeta potential. Electron microscopy revealed smooth surfaces and a spherical shape, showing that the nanoparticle addition was not deleterious. The A-GQD microbubbles were specifically detectable using DAPI-filtering with fluorescence microscopy and had the highest TRITC-filtered fluorescence. The C-GQD microbubbles had the highest loading efficiency at 59.4% ( p < .05), and the lowest max acoustic enhancement at 5 MHz (U = 19.8, C = 17.6, A = 18.9, Unloaded = 18.5 dB; p < .05). Additionally, all microbubbles were visible and susceptible to inertial cavitation utilizing clinical ultrasound. The A-GQDs showed promise toward improving the theranostic capabilities of the microbubble platform. They have imbued the most advantageous fluorescence capability and slightly improved backscatter enhancement while retaining all the necessary capabilities of an ultrasound contrast agent. Future studies will investigate the coloading potential of A-GQDs and drug within microbubbles.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Drexel University School of Biomedical Engineering Science and Health Systems, Philadelphia, PA, USA.
- Thomas Jefferson University, Philadelphia, PA, USA.
- Drexel University, Philadelphia, PA, USA.
ORCID-Profile: Matthew A Shirley, John Eisenbrey
Förderung
- National Science Foundation Graduate Research Fellowship Program
Zitieren
APA
Shirley, M. A., Arango-Aliaga, V., Patel, A., Oeffinger, B. E., Eisenbrey, J., & Wheatley, M. A. (2025). Development of a Polymer Ultrasound Contrast Agent Incorporating Nested Carbon Nanodots. Ultrasonic Imaging. https://doi.org/10.1177/01617346241279112
Vancouver
Shirley MA, Arango-Aliaga V, Patel A, Oeffinger BE, Eisenbrey J, Wheatley MA. Development of a Polymer Ultrasound Contrast Agent Incorporating Nested Carbon Nanodots. Ultrasonic Imaging. 2025. doi:10.1177/01617346241279112