EUVIMEDEUVIMED entdecken
Crossref

Pulmonary Transit Time Assessment by CEUS in Healthy Rabbits: Feasibility, and the Effects of UCAs Dilution Concentration

Song Kang, Jianfeng Chen, He Zhang, Guangyin Li, Yingying Liu, Xue Mei, Binyang Zhu, Xin Ai, Shuangquan Jiang iD

Ultrasonic Imaging · 2024

DOI: 10.1177/01617346241246169 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultrasonic Imaging, 2024. Verfasst von Song Kang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China. Hauptthemen laut MEDLINE: Feasibility Studies, Contrast Media, Ultrasonography, Observer Variation. Die Arbeit nennt 23 Literaturangaben. Gefördert von: the Natural Science Foundation of Heilongjiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To evaluate the inter-observer variability and the intra-observer repeatability of pulmonary transit time (PTT) measurement using contrast-enhanced ultrasound (CEUS) in healthy rabbits, and assess the effects of dilution concentration of ultrasound contrast agents (UCAs) on PTT. Thirteen healthy rabbits were selected, and five concentrations UCAs of 1:200, 1:100, 1:50, 1:10, and 1:1 were injected into the right ear vein. Five digital loops were obtained from the apical 4-chamber view. Four sonographers obtained PTT by plotting the TIC of right atrium (RA) and left atrium (LA) at two time points (T1 and T2). The frame counts of the first appearance of UCAs in RA and LA had excellent inter-observer agreement, with intra-class correlations (ICC) of 0.996, 0.988, respectively. The agreement of PTT among four observers was all good at five different concentrations, with an ICC of 0.758–0.873. The reproducibility of PTT obtained by four observers at T1 and T2 was performed well, with ICC of 0.888–0.961. The median inter-observer variability across 13 rabbits was 6.5% and the median variability within 14 days for 4 observers was 1.9%, 1.7%, 2.2%, 1.9%, respectively; The PTT of 13 healthy rabbits is 1.01 ± 0.18 second. The difference of PTT between five concentrations is statistically significant. The PTT obtained by a concentration of 1:200 and 1:100 were higher than that of 1:1, while there were no significantly differences in PTT of a concentration of 1:1, 1:10, and 1:50. PTT measured by CEUS in rabbits is feasible, with excellent inter-observer and intra-observer reliability and reproducibility, and dilution concentration of UCAs influences PTT results.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Feasibility StudiesContrast MediaUltrasonographyObserver VariationAnimalsRabbitsReproducibility of ResultsSulfur HexafluoridePulmonary Circulation

Stichwörter der Autor:innen

contrast-enhanced ultrasounddilution concentrationhealthy rabbitspulmonary transit timeultrasound contrast agents

Substanzen

Contrast MediaSulfur Hexafluoride

Autor:innen und Institutionen

  • Department of Ultrasound Medicine, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
  • Department of ultrasound, Chengdu Seventh People's Hospital (Affiliated Cancer Hospital of Chengdu Medical College), Chengdu, China.
  • Laboratory Animal Center, The Second Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.

ORCID-Profile: Shuangquan Jiang

Förderung

  • the Natural Science Foundation of Heilongjiang Province

Zitieren

APA

Kang, S., Chen, J., Zhang, H., Li, G., Liu, Y., Mei, X., Zhu, B., Ai, X., & Jiang, S. (2024). Pulmonary Transit Time Assessment by CEUS in Healthy Rabbits: Feasibility, and the Effects of UCAs Dilution Concentration. Ultrasonic Imaging. https://doi.org/10.1177/01617346241246169

Vancouver

Kang S, Chen J, Zhang H, Li G, Liu Y, Mei X, et al. Pulmonary Transit Time Assessment by CEUS in Healthy Rabbits: Feasibility, and the Effects of UCAs Dilution Concentration. Ultrasonic Imaging. 2024. doi:10.1177/01617346241246169

BibTeX
@article{Kang2024,
  author = {Kang, Song and Chen, Jianfeng and Zhang, He and Li, Guangyin and Liu, Yingying and Mei, Xue and Zhu, Binyang and Ai, Xin and Jiang, Shuangquan},
  title = {Pulmonary Transit Time Assessment by CEUS in Healthy Rabbits: Feasibility, and the Effects of UCAs Dilution Concentration},
  journal = {Ultrasonic Imaging},
  year = {2024},
  doi = {10.1177/01617346241246169}
}
Kostenlos starten →