EUVIMEDEUVIMED entdecken
Crossref

Semi-automatic Breast Ultrasound Image Segmentation Based on Mean Shift and Graph Cuts

Zhuhuang Zhou, Weiwei Wu, Shuicai Wu, Po-Hsiang Tsui, Chung-Chih Lin, Ling Zhang, Tianfu Wang

Ultrasonic Imaging · 2014-10 · 36 (4) · 256-276

DOI: 10.1177/0161734614524735 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultrasonic Imaging, online erschienen am 22.04.2014. Verfasst von Zhuhuang Zhou und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China. Hauptthemen laut MEDLINE: Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Computerized tumor segmentation on breast ultrasound (BUS) images remains a challenging task. In this paper, we proposed a new method for semi-automatic tumor segmentation on BUS images using Gaussian filtering, histogram equalization, mean shift, and graph cuts. The only interaction required was to select two diagonal points to determine a region of interest (ROI) on an input image. The ROI image was shrunken by a factor of 2 using bicubic interpolation to reduce computation time. The shrunken image was smoothed by a Gaussian filter and then contrast-enhanced by histogram equalization. Next, the enhanced image was filtered by pyramid mean shift to improve homogeneity. The object and background seeds for graph cuts were automatically generated on the filtered image. Using these seeds, the filtered image was then segmented by graph cuts into a binary image containing the object and background. Finally, the binary image was expanded by a factor of 2 using bicubic interpolation, and the expanded image was processed by morphological opening and closing to refine the tumor contour. The method was implemented with OpenCV 2.4.3 and Visual Studio 2010 and tested for 38 BUS images with benign tumors and 31 BUS images with malignant tumors from different ultrasound scanners. Experimental results showed that our method had a true positive rate (TP) of 91.7%, a false positive (FP) rate of 11.9%, and a similarity (SI) rate of 85.6%. The mean run time on Intel Core 2.66 GHz CPU and 4 GB RAM was 0.49 ± 0.36 s. The experimental results indicate that the proposed method may be useful in BUS image segmentation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Interpretation, Computer-AssistedAlgorithmsBreast NeoplasmsChinaFalse Positive ReactionsFemaleHumansImage EnhancementUltrasonography, Mammary

Stichwörter der Autor:innen

OpenCVbreast ultrasoundgraph cutsmean shiftsemi-automatic segmentation

Autor:innen und Institutionen

  • College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China.
  • College of Electronic Information and Control Engineering, Beijing University of Technology, Beijing, China.
  • College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China wushuicai@bjut.edu.cn tsuiph@mail.cgu.edu.tw.
  • Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan wushuicai@bjut.edu.cn tsuiph@mail.cgu.edu.tw.
  • Department of Computer Science and Information Engineering, Chang Gung University, Taoyuan, Taiwan.
  • Department of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China.

Zitieren

APA

Zhou, Z., Wu, W., Wu, S., Tsui, P. H., Lin, C. C., Zhang, L., & Wang, T. (2014). Semi-automatic Breast Ultrasound Image Segmentation Based on Mean Shift and Graph Cuts. Ultrasonic Imaging, 36(4), 256-276. https://doi.org/10.1177/0161734614524735

Vancouver

Zhou Z, Wu W, Wu S, Tsui PH, Lin CC, Zhang L, et al. Semi-automatic Breast Ultrasound Image Segmentation Based on Mean Shift and Graph Cuts. Ultrasonic Imaging. 2014;36(4):256-276. doi:10.1177/0161734614524735

BibTeX
@article{Zhou2014,
  author = {Zhou, Zhuhuang and Wu, Weiwei and Wu, Shuicai and Tsui, Po-Hsiang and Lin, Chung-Chih and Zhang, Ling and Wang, Tianfu},
  title = {Semi-automatic Breast Ultrasound Image Segmentation Based on Mean Shift and Graph Cuts},
  journal = {Ultrasonic Imaging},
  year = {2014},
  volume = {36},
  number = {4},
  pages = {256--276},
  doi = {10.1177/0161734614524735}
}
Kostenlos starten →