The investigation of the impact of new ICRU95 operational quantities on the reference fields at JAEA-FRS in terms of the type-testing of the dosimeters
Annals of the ICRP · 28.05.2026
DOI: 10.1177/01466453251411986 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of the ICRP, online erschienen am 28.05.2026. Verfasst von H Yoshitomi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4, Shirakata, Tokai, Naka, Ibaraki, 319-1195, Japan; e-mail: yoshitomi.hiroshi@jaea…. Die Arbeit nennt 9 Literaturangaben.
Abstract (Originalsprache)
ICRU has published Report 95 jointly with ICRP in 2020 proposing new operational quantities. This will impact dosimetry in radiological protection especially for the dosimeters’ performance of energy and angular dependence. To test the performance in detail, it is important to establish radiation reference fields corresponding to the new quantities. The Facility of Radiation Standards (FRS) of the Japan Atomic Energy Agency is a comprehensive Secondary Standard Dosimetry Laboratory in Japan equipped with various reference fields for x-, gamma-, beta-, and neutron radiations. We evaluated the conversion coefficients in terms of the new quantities in the FRS fields and demonstrated type-testing of commercial dosimeters based on the new quantities, which made it possible to conduct the performance tests of the dosimeters in terms of the new quantities at the FRS. Significant differences between the conversion coefficients for new and existing operational quantities were found for some FRS fields, especially for x-ray fields with low energies and large angles, beta-ray fields on the operational quantities for eye lens monitoring, and neutron radiation fields. The H * and H p responses of the dosimeters were found to be affected at low-energy photon region accordingly.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Nuclear Science Research Institute, Japan Atomic Energy Agency, 2-4, Shirakata, Tokai, Naka, Ibaraki, 319-1195, Japan; e-mail: yoshitomi.hiroshi@jaea.go.jp.
Zitieren
APA
Yoshitomi, H., Tsuji, T., Nishino, S., & Tanimura, Y. (2026). The investigation of the impact of new ICRU95 operational quantities on the reference fields at JAEA-FRS in terms of the type-testing of the dosimeters. Annals of the ICRP. https://doi.org/10.1177/01466453251411986
Vancouver
Yoshitomi H, Tsuji T, Nishino S, Tanimura Y. The investigation of the impact of new ICRU95 operational quantities on the reference fields at JAEA-FRS in terms of the type-testing of the dosimeters. Annals of the ICRP. 2026. doi:10.1177/01466453251411986
BibTeX
@article{Yoshitomi2026,
author = {Yoshitomi, H and Tsuji, T and Nishino, S and Tanimura, Y},
title = {The investigation of the impact of new ICRU95 operational quantities on the reference fields at JAEA-FRS in terms of the type-testing of the dosimeters},
journal = {Annals of the ICRP},
year = {2026},
doi = {10.1177/01466453251411986}
}