Reliability Evaluation of a Portable Active Noise Control-Integrated Audiometer for Clinical Hearing Assessment
Ear, Nose & Throat Journal · 2025
DOI: 10.1177/01455613251385770 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Ear, Nose & Throat Journal, 2025. Verfasst von Qianjin Gao und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, Shaanxi Province, China. Hauptthemen laut MEDLINE: Audiometry, Pure-Tone, Hearing Loss. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Natural Science Foundation of China, Shaanxi Health Commission Research Innovation Platform Development Plan, Key Research and Development Plan of Shaanxi Province.
Abstract (Originalsprache)
Purpose
Hearing loss is a major global health challenge, and pure-tone audiometry remains the gold standard for assessing auditory thresholds. However, conventional clinical audiometry requires specialized sound-proof booths, which limit its accessibility in resource-constrained settings. To address this limitation, we developed and evaluated a portable audiometry system, designated as the E200, incorporating active noise control (ANC) technology with integrated supra-aural earphones.
Methods
In this 2-phase study, reference equivalent threshold sound pressure level calibration was first performed on 183 volunteers comparing E200 to conventional clinical pure-tone audiometric testing. Subsequently, we prospectively enrolled 114 participants with diverse otologic pathologies from tertiary otology clinics to evaluate the validity of the E200 audiometric system.
Results
Data from 228 ears were collected from 114 participants, with 7 frequencies tested/ear, resulting in 1596 sets of data. The two one-sided test equivalence analysis demonstrated that all tested frequencies met the equivalence criterion at the ±5 dB margin. Pure-tone average (PTA) was derived from the arithmetic mean of air-conduction thresholds at standard speech frequencies (0.5, 1, 2, and 4 kHz), with hearing loss severity classified according to WHO (2021) criteria: normal (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, Shaanxi Province, China.
- School of Aerospace Medicine, Center of Clinical Aerospace Medicine, Air Force Military Medical University, Xi'an, Shaanxi Province, China.
- 989th Hospital of People's Liberation Army Joint Logistic Support Force, Luoyang, Henan Province, China.
ORCID-Profile: Qianjin Gao, Cuncun Ren, Xiaoqin Fan, Minjiao Wang, Yongshou Liu, Xiaogang An, Xinyu Dong, Xiaocheng Wang, Lihui Zhou, Jianhua Qiu, Jun Chen, Dingjun Zha
Förderung
- National Natural Science Foundation of China
- Shaanxi Health Commission Research Innovation Platform Development Plan
- Key Research and Development Plan of Shaanxi Province
- Interdisciplinary Integration Program of Air Force Medical University
- Shaanxi Provincial Science and Technology Research Fund
- Shaanxi Key Industrial Chain Project
- Innovative Talent Promotion Plan of Shaanxi Province
Zitieren
APA
Gao, Q., Ren, C., Fan, X., Wang, M., Liu, Y., An, X., Dong, X., Wang, X., Zhou, L., Qiu, J., Chen, J., & Zha, D. (2025). Reliability Evaluation of a Portable Active Noise Control-Integrated Audiometer for Clinical Hearing Assessment. Ear, Nose & Throat Journal. https://doi.org/10.1177/01455613251385770
Vancouver
Gao Q, Ren C, Fan X, Wang M, Liu Y, An X, et al. Reliability Evaluation of a Portable Active Noise Control-Integrated Audiometer for Clinical Hearing Assessment. Ear, Nose & Throat Journal. 2025. doi:10.1177/01455613251385770
BibTeX
@article{Gao2025,
author = {Gao, Qianjin and Ren, Cuncun and Fan, Xiaoqin and Wang, Minjiao and Liu, Yongshou and An, Xiaogang and Dong, Xinyu and Wang, Xiaocheng and Zhou, Lihui and Qiu, Jianhua and Chen, Jun and Zha, Dingjun},
title = {Reliability Evaluation of a Portable Active Noise Control-Integrated Audiometer for Clinical Hearing Assessment},
journal = {Ear, Nose & Throat Journal},
year = {2025},
doi = {10.1177/01455613251385770}
}
EUVIMED