This paper proposes a supervisory control framework for a 6-MW wind farm (WF) comprising four 1.5-MW doubly fed induction generator (DFIG)-based wind turbines (WTs) to improve power quality and mitigate electrical and mechanical stresses under grid-pollution conditions. A backstepping control (BC) strategy is implemented at each WT to regulate active and reactive power while enabling active harmonic compensation through the existing power-electronic converters. A proportional allocation algorithm coordinates the compensation effort among the available WTs according to the load-current magnitude, thereby allowing partial or full-WF harmonic compensation depending on the operating condition. MATLAB/Simulink simulations under variable wind speeds, with an average wind speed of approximately 8.2 m/s, demonstrate accurate tracking of the WF-level active and reactive power references, with steady-state errors below 1.4%. Under nonlinear-load conditions, the proposed compensation strategy reduces the grid-current total harmonic distortion (THD) from 43.02% to 1.37% and from 33.16% to 1.33%, corresponding to reductions of approximately 96.8154% and 95.9891%, while improving the power factor from 0.78 lagging to 0.998. In addition, the rotor-circuit current ripple and electromagnetic torque ripple are reduced by 42% and 37%, respectively, indicating reduced electrical and mechanical stress on the DFIG-based WTs. These results demonstrate that the proposed supervisory and BC-based compensation framework can simultaneously achieve effective power regulation, harmonic mitigation, and stress reduction without requiring dedicated additional active-filter converters.
Zitieren
APA
Achar, A., Djeriri, Y., Benbouhenni, H., Hanafi, S., Bentaallah, A., Blazek, V., Mahmoud, M. M., Mbasso, W. F., Kamel, O. M., & Abdelaal, G. F. (2026). Integrated supervisory backstepping control and proportional harmonic compensation for DFIG-based wind farms under grid pollution. Energy Exploration & Exploitation. https://doi.org/10.1177/01445987261503780
Vancouver
Achar A, Djeriri Y, Benbouhenni H, Hanafi S, Bentaallah A, Blazek V, et al. Integrated supervisory backstepping control and proportional harmonic compensation for DFIG-based wind farms under grid pollution. Energy Exploration & Exploitation. 2026. doi:10.1177/01445987261503780
BibTeX
@article{Achar2026,
author = {Achar, Abdelkader and Djeriri, Youcef and Benbouhenni, Habib and Hanafi, Salah and Bentaallah, Abderrahim and Blazek, Vojtech and Mahmoud, Mohamed Metwally and Mbasso, Wulfran Fendzi and Kamel, Omar Makram and Abdelaal, Galal F},
title = {Integrated supervisory backstepping control and proportional harmonic compensation for DFIG-based wind farms under grid pollution},
journal = {Energy Exploration & Exploitation},
year = {2026},
doi = {10.1177/01445987261503780}
}
EUVIMED