EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Integrated supervisory backstepping control and proportional harmonic compensation for DFIG-based wind farms under grid pollution

Abdelkader Achar, Youcef Djeriri, Habib Benbouhenni, Salah Hanafi, Abderrahim Bentaallah, Vojtech Blazek, Mohamed Metwally Mahmoud, Wulfran Fendzi Mbasso, Omar Makram Kamel, Galal F Abdelaal

Energy Exploration & Exploitation · 27.10.2026

DOI: 10.1177/01445987261503780 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energy Exploration & Exploitation, online erschienen am 27.10.2026. Verfasst von Abdelkader Achar und 9 weiteren Autor:innen. Die Arbeit nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper proposes a supervisory control framework for a 6-MW wind farm (WF) comprising four 1.5-MW doubly fed induction generator (DFIG)-based wind turbines (WTs) to improve power quality and mitigate electrical and mechanical stresses under grid-pollution conditions. A backstepping control (BC) strategy is implemented at each WT to regulate active and reactive power while enabling active harmonic compensation through the existing power-electronic converters. A proportional allocation algorithm coordinates the compensation effort among the available WTs according to the load-current magnitude, thereby allowing partial or full-WF harmonic compensation depending on the operating condition. MATLAB/Simulink simulations under variable wind speeds, with an average wind speed of approximately 8.2 m/s, demonstrate accurate tracking of the WF-level active and reactive power references, with steady-state errors below 1.4%. Under nonlinear-load conditions, the proposed compensation strategy reduces the grid-current total harmonic distortion (THD) from 43.02% to 1.37% and from 33.16% to 1.33%, corresponding to reductions of approximately 96.8154% and 95.9891%, while improving the power factor from 0.78 lagging to 0.998. In addition, the rotor-circuit current ripple and electromagnetic torque ripple are reduced by 42% and 37%, respectively, indicating reduced electrical and mechanical stress on the DFIG-based WTs. These results demonstrate that the proposed supervisory and BC-based compensation framework can simultaneously achieve effective power regulation, harmonic mitigation, and stress reduction without requiring dedicated additional active-filter converters.

Zitieren

APA

Achar, A., Djeriri, Y., Benbouhenni, H., Hanafi, S., Bentaallah, A., Blazek, V., Mahmoud, M. M., Mbasso, W. F., Kamel, O. M., & Abdelaal, G. F. (2026). Integrated supervisory backstepping control and proportional harmonic compensation for DFIG-based wind farms under grid pollution. Energy Exploration & Exploitation. https://doi.org/10.1177/01445987261503780

Vancouver

Achar A, Djeriri Y, Benbouhenni H, Hanafi S, Bentaallah A, Blazek V, et al. Integrated supervisory backstepping control and proportional harmonic compensation for DFIG-based wind farms under grid pollution. Energy Exploration & Exploitation. 2026. doi:10.1177/01445987261503780

BibTeX
@article{Achar2026,
  author = {Achar, Abdelkader and Djeriri, Youcef and Benbouhenni, Habib and Hanafi, Salah and Bentaallah, Abderrahim and Blazek, Vojtech and Mahmoud, Mohamed Metwally and Mbasso, Wulfran Fendzi and Kamel, Omar Makram and Abdelaal, Galal F},
  title = {Integrated supervisory backstepping control and proportional harmonic compensation for DFIG-based wind farms under grid pollution},
  journal = {Energy Exploration & Exploitation},
  year = {2026},
  doi = {10.1177/01445987261503780}
}
Kostenlos starten →