EUVIMEDEUVIMED entdecken
Crossref

Dynamic KNX-based energy management system with machine learning for energy optimization

Hala Rabih Fatayerji, Naveed Anwar, Muhammad Samee Baig, Omar Kittaneh, Enfel Barkat, Mohammed Abdulmajid

Building Services Engineering Research & Technology · 06.11.2026

DOI: 10.1177/01436244261503395 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Building Services Engineering Research & Technology, online erschienen am 06.11.2026. Verfasst von Hala Rabih Fatayerji und 5 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Efficient energy management in residential buildings is essential for reducing consumption and supporting sustainability initiatives. Conventional Energy Management Systems (EMS) often rely on static control strategies that do not reflect dynamic occupancy patterns, limiting their capacity to optimize performance. This study presents a dynamic KNX-based EMS that integrates real-time occupancy sensing with machine learning models to support forecast-assisted energy management of building energy systems. A residential building in Jeddah, Saudi Arabia, equipped with a 200-kW photovoltaic array and a 100-kW inverter, was simulated using HOMER Pro. High-resolution data from lighting, HVAC, and occupancy sensors were analyzed separately and compared after hourly aggregation to characterize building energy demand. The Solace dataset was then separated into 70% training and 30% testing subsets for ML model development and validation. Four predictive models: Support Vector Regression (SVR), Random Forest (RF), Gradient Boosting (GBM), and Multilayer Perceptron (MLP) were trained and tuned using Bayesian optimization and five-fold cross-validation. The integration of KNX occupancy controls resulted in an average hourly energy reduction of 15.33% over the 41-day monitoring period relative to the HOMER baseline, while the SVR-predicted annual energy consumption was 313,239.12 kWh, corresponding to a difference of 61,798.88 kWh (16.48%) relative to the HOMER baseline. Among the evaluated models, RF achieved the highest large-scale accuracy, while SVR offered the best balance between accuracy and computational cost at the moderate data scale. These findings suggest that integrating dynamic KNX automation with machine learning supports forecast-assisted, data-driven energy management of residential energy systems, providing a scalable strategy for enhancing energy efficiency in smart buildings.

Zitieren

APA

Fatayerji, H. R., Anwar, N., Baig, M. S., Kittaneh, O., Barkat, E., & Abdulmajid, M. (2026). Dynamic KNX-based energy management system with machine learning for energy optimization. Building Services Engineering Research & Technology. https://doi.org/10.1177/01436244261503395

Vancouver

Fatayerji HR, Anwar N, Baig MS, Kittaneh O, Barkat E, Abdulmajid M. Dynamic KNX-based energy management system with machine learning for energy optimization. Building Services Engineering Research & Technology. 2026. doi:10.1177/01436244261503395

BibTeX
@article{Fatayerji2026,
  author = {Fatayerji, Hala Rabih and Anwar, Naveed and Baig, Muhammad Samee and Kittaneh, Omar and Barkat, Enfel and Abdulmajid, Mohammed},
  title = {Dynamic KNX-based energy management system with machine learning for energy optimization},
  journal = {Building Services Engineering Research & Technology},
  year = {2026},
  doi = {10.1177/01436244261503395}
}