Tendon-based power transmission mechanism and collocated controller with application to position tracking of autonomous surgical robots
Transactions of the Institute of Measurement and Control · 2026-12 · 48 (16) · 5068-5077
DOI: 10.1177/01423312261425524 ↗Kurz gefasst
Fachartikel in der Zeitschrift Transactions of the Institute of Measurement and Control, online erschienen am 15.03.2026. Verfasst von Hongbing Li und 5 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Joint Fund of Scientific Research for the Public Hospitals of Inner Mongolia Academy of Medical Sciences, Key Technology Breakthrough Plan Project of Science and Innovation Yongjiang 2035.
Abstract (Originalsprache)
Due to compliance and significant friction in the drive mechanism, tendon-based minimally invasive surgical robot systems exhibit highly nonlinear behavior and low position control accuracy. In this study, a novel power transmission mechanism incorporating both tendon position and tension feedback was developed. The mechanism is controlled by a corresponding collocated controller based on position sensing and a cable tension sensing method, which enables compensation for nonlinearities in the motion transmission of the tendon-based surgical robot system. The collocated controller was implemented and experimentally validated on a surgical instrument utilizing the power transmission mechanism. Experimental results demonstrate that position tracking in the motion transmission of the tendon-driven instrument can be improved by 80% using the proposed mechanism and controller. This advancement in robotic surgery holds significant potential to enhance the precision and effectiveness of surgical procedures.
Förderung
- National Natural Science Foundation of China
- Joint Fund of Scientific Research for the Public Hospitals of Inner Mongolia Academy of Medical Sciences
- Key Technology Breakthrough Plan Project of Science and Innovation Yongjiang 2035
Zitieren
APA
Li, H., Lan, Y., Li, L., Bao, Q., Wang, R., & Magid, E. (2026). Tendon-based power transmission mechanism and collocated controller with application to position tracking of autonomous surgical robots. Transactions of the Institute of Measurement and Control, 48(16), 5068-5077. https://doi.org/10.1177/01423312261425524
Vancouver
Li H, Lan Y, Li L, Bao Q, Wang R, Magid E. Tendon-based power transmission mechanism and collocated controller with application to position tracking of autonomous surgical robots. Transactions of the Institute of Measurement and Control. 2026;48(16):5068-5077. doi:10.1177/01423312261425524
BibTeX
@article{Li2026,
author = {Li, Hongbing and Lan, Yubin and Li, Linlong and Bao, Qilian and Wang, Rui and Magid, Evgeni},
title = {Tendon-based power transmission mechanism and collocated controller with application to position tracking of autonomous surgical robots},
journal = {Transactions of the Institute of Measurement and Control},
year = {2026},
volume = {48},
number = {16},
pages = {5068--5077},
doi = {10.1177/01423312261425524}
}
EUVIMED