Validierungsstudie in der Zeitschrift Tropical Doctor, online erschienen am 23.07.2024. Verfasst von Chandan Kumar Jha und 4 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor, Department of General Surgery (Endocrine Surgery), All India Institute of Medical Sciences, Patna, India. Hauptthemen laut MEDLINE: Methylene Blue, Sentinel Lymph Node Biopsy, Breast Neoplasms, Fluorescein. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The availability of radioisotopes for sentinel lymph node biopsy (SLNB) in breast carcinoma is limited in low- and middle-income countries and thus the need for other reliable tracers exists. We aimed to validate the effectiveness of fluorescein sodium (FS) together with methylene blue dye (MBD) for patients with node-negative early breast carcinoma in a prospective cross-sectional study. Patients underwent SLNB using FS and MBD followed by axillary dissection to validate results. Sentinel lymph node (SLN) identification rate and false negative rate were assessed for all three tracers/combinations (MBD, FS, and MBD + FS). We concluded that SLNB using a combination of FS and MBD has an acceptable rate of SLN identification but the addition of FS provided no additional benefit.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Methylene BlueSentinel Lymph Node BiopsyBreast NeoplasmsFluoresceinHumansFemaleProspective StudiesCross-Sectional StudiesMiddle AgedAdultAgedSentinel Lymph NodeColoring AgentsAxillaLymphatic MetastasisFalse Negative Reactions

Stichwörter der Autor:innen

Sentinel lymph node biopsyearly breast cancerfluorescein sodiummethylene bluenode-negative breast cancer

Substanzen

Methylene BlueFluoresceinColoring Agents

Autor:innen und Institutionen

  • Associate Professor, Department of General Surgery (Endocrine Surgery), All India Institute of Medical Sciences, Patna, India.
  • Additional Professor, Department of Radiodiagnosis, All India Institute of Medical Sciences, Patna, India.
  • Professor, Department of General Surgery, All India Institute of Medical Sciences, Patna, India.
  • Associate Professor, Department of Surgical Gastroenterology, All India Institute of Medical Sciences, Patna, India.

ORCID-Profile: Chandan Kumar Jha

Zitieren

APA

Jha, C. K., Sinha, U., Singh, P. K., Parasar, K., & Kumar, M. (2024). Sentinel lymph node biopsy in early breast carcinoma using fluorescein sodium and methylene blue dye: A validation study. Tropical Doctor, 54(4), 340-345. https://doi.org/10.1177/00494755241264043

Vancouver

Jha CK, Sinha U, Singh PK, Parasar K, Kumar M. Sentinel lymph node biopsy in early breast carcinoma using fluorescein sodium and methylene blue dye: A validation study. Tropical Doctor. 2024;54(4):340-345. doi:10.1177/00494755241264043

BibTeX
@article{Jha2024,
  author = {Jha, Chandan Kumar and Sinha, Upasna and Singh, Prashant Kumar and Parasar, Kunal and Kumar, Manoj},
  title = {Sentinel lymph node biopsy in early breast carcinoma using fluorescein sodium and methylene blue dye: A validation study},
  journal = {Tropical Doctor},
  year = {2024},
  volume = {54},
  number = {4},
  pages = {340--345},
  doi = {10.1177/00494755241264043}
}
Kostenlos starten →