EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access · CC BY-NC 4.0

Treatment of posterior wall acetabular fractures via the direct posterior approach using a seagull-shaped plate: A retrospective cohort study

Shuaixian Tao iD, Yurong Zhao iD, Jidong Wang iD, Shaofeng Xu iD, Jifa Hou iD, Baoxin Li iD, Qiang Wang iD, Rong Ren iD, Zhonglin Lu iD, Zhaowei Li iD

Science Progress · 2026

DOI: 10.1177/00368504251413441 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Science Progress, 2026. Verfasst von Shuaixian Tao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Pediatric Surgery Department, Zibo Central Hospital, Zibo, Shandong, China. Hauptthemen laut MEDLINE: Acetabulum, Bone Plates, Fractures, Bone, Fracture Fixation, Internal. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the clinical efficacy of the direct posterior approach (DPA) with seagull-shaped plate fixation for treating posterior wall acetabular fractures.

Methods

A retrospective cohort study of 17 patients (8 male, 9 female) with posterior wall acetabular fractures treated with DPA seagull-shaped plate fixation was conducted. Postoperative pelvic X-ray imaging and computed tomography were performed, and the quality of acetabular reduction was evaluated using the Matta score. The Merle d’Aubigné & Bone score, as modified by Matta, was used to assess hip joint function.

Results

The mean ± standard deviation surgical incision length, operating time, and intraoperative blood loss were 9.7 ± 0.6 cm, 48.7 ± 9.1 min, and 235.3 ± 65.6 mL, respectively. According to the Matta score, 11 patients achieved excellent reduction quality, and six had good reduction quality, resulting in a 100% combined excellent or good reduction rate. All patients had good fracture healing, with a healing time of 9.7 ± 1.6 weeks. The modified Merle d'Aubigné & Bone score was 17.0 ± 1.6, with 11, 4, 2, and 0 patients rated as excellent, good, fair, and poor, respectively, yielding an 88.2% excellent or good outcome rate. Postoperative complications included fat liquefaction in one patient and deep vein thrombosis in the lower limbs of two patients, with an overall complication rate of 17.6%.

Conclusions

DPA with seagull-shaped plate fixation provides satisfactory clinical outcomes for posterior wall acetabular fractures, improving patients’ living ability and quality of life.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AcetabulumBone PlatesFractures, BoneFracture Fixation, InternalHumansFemaleRetrospective StudiesMaleMiddle AgedAdultTreatment OutcomeAgedFracture Healing

Stichwörter der Autor:innen

Direct posterior approachK–L approachposterior wall acetabular fracturereconstructed steel plateseagull-shaped plate

Autor:innen und Institutionen

  • Pediatric Surgery Department, Zibo Central Hospital, Zibo, Shandong, China.
  • Trauma Orthopedics Department, Qinghai University Affiliated Hospital, Xining, Qinghai, China.
  • Zhongshan Traditional Chinese Medicine Hospital, Zhongshan, Guangdong, China.
  • Orthopedics Department, Haixi People's Hospital, Delingha City, Haixi, Qinghai, China.
  • Orthopedics Department, Nanyang Traditional Chinese Medicine Hospital, Nanyang, Henan, China.
  • Orthopedics Department, Zhangye Second People's Hospital, Zhangye, Gansu, China.

ORCID-Profile: Shuaixian Tao, Yurong Zhao, Jidong Wang, Shaofeng Xu, Jifa Hou, Baoxin Li, Qiang Wang, Rong Ren, Zhonglin Lu, Zhaowei Li

Zitieren

APA

Tao, S., Zhao, Y., Wang, J., Xu, S., Hou, J., Li, B., Wang, Q., Ren, R., Lu, Z., & Li, Z. (2026). Treatment of posterior wall acetabular fractures via the direct posterior approach using a seagull-shaped plate: A retrospective cohort study. Science Progress. https://doi.org/10.1177/00368504251413441

Vancouver

Tao S, Zhao Y, Wang J, Xu S, Hou J, Li B, et al. Treatment of posterior wall acetabular fractures via the direct posterior approach using a seagull-shaped plate: A retrospective cohort study. Science Progress. 2026. doi:10.1177/00368504251413441

BibTeX
@article{Tao2026,
  author = {Tao, Shuaixian and Zhao, Yurong and Wang, Jidong and Xu, Shaofeng and Hou, Jifa and Li, Baoxin and Wang, Qiang and Ren, Rong and Lu, Zhonglin and Li, Zhaowei},
  title = {Treatment of posterior wall acetabular fractures via the direct posterior approach using a seagull-shaped plate: A retrospective cohort study},
  journal = {Science Progress},
  year = {2026},
  doi = {10.1177/00368504251413441}
}
Kostenlos starten →