Fachartikel in der Zeitschrift Science Progress, 2025. Verfasst von Huijing Huang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China. Hauptthemen laut MEDLINE: Electromyography, Wearable Electronic Devices, Spinal Curvatures. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Platform Project of the Big Data Research Center for Traditional Chinese Medicine at Guangzhou University of Chinese Medicine, Special Funds for Cultivation of Science and Technology Innovation for Guangdong University Students, Humanities and Social Sciences Research Project of Guangzhou University of Chinese Medicine in 2024.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Abnormal spinal curvature poses a significant health risk to children and adolescents, highlighting the importance of maintaining good posture for spinal health. However, current posture detection methods face challenges such as insufficient detection accuracy, discomfort during use, and overall inconvenience. This study aims to design and implement a wearable system that integrates angle sensors and surface electromyography (sEMG) sensors to monitor spinal alignment and muscle activity in real-time. The system consists of a smart vest equipped with flexible bending sensors and sEMG electrodes, a microcontroller unit for data processing, and a mobile application for data visualization and user feedback. To validate the system's effectiveness, the study involved 65 eligible undergraduate students wearing the device, collecting sEMG signals under different posture conditions, and conducting posture analysis to evaluate the device's performance. The results showed a significant correlation between asymmetric paraspinal muscle activity and the direction of the spinal curve, with the system achieving an accuracy rate of 90.8% in predicting the curve direction using a logistic regression model. Although the system verifies spinal alignment through indirect measurement rather than direct imaging, the high consistency between sEMG asymmetry and expected biomechanical patterns supports its reliability as a functional screening tool. Wearable devices can provide timely posture correction reminders and personalized rehabilitation plans, offering a noninvasive, user-friendly solution for the prevention and rehabilitation of spinal curvature abnormalities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectromyographyWearable Electronic DevicesSpinal CurvaturesHumansMaleFemalePostureAdolescentYoung AdultEquipment DesignSpine

Stichwörter der Autor:innen

Hunchbackcorrectionrehabilitationscoliosissensorswearable

Autor:innen und Institutionen

  • Fifth Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • School of Medical Information Engineering, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • Clinical College of Acupuncture and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.

ORCID-Profile: Wei Gong, Fang Mei

Förderung

  • Platform Project of the Big Data Research Center for Traditional Chinese Medicine at Guangzhou University of Chinese Medicine
  • Special Funds for Cultivation of Science and Technology Innovation for Guangdong University Students
  • Humanities and Social Sciences Research Project of Guangzhou University of Chinese Medicine in 2024
  • Supply-Demand Collaboration and Employment-Oriented Talent Development Program of the Ministry of Education
  • College Students’Innovation and Entrepreneurship Training Program

Zitieren

APA

Huang, H., Gong, W., Chen, Z., Mei, F., Deng, J., Wu, N., Hong, C., Qiu, S., & Zhao, X. (2025). Design and research of a wearable system for spinal deformity rehabilitation based on curvature and electromyography sensors. Science Progress. https://doi.org/10.1177/00368504251387233

Vancouver

Huang H, Gong W, Chen Z, Mei F, Deng J, Wu N, et al. Design and research of a wearable system for spinal deformity rehabilitation based on curvature and electromyography sensors. Science Progress. 2025. doi:10.1177/00368504251387233

BibTeX
@article{Huang2025,
  author = {Huang, Huijing and Gong, Wei and Chen, Ziran and Mei, Fang and Deng, Jiahui and Wu, Nianzu and Hong, Chuhan and Qiu, Shengyu and Zhao, Xinyan},
  title = {Design and research of a wearable system for spinal deformity rehabilitation based on curvature and electromyography sensors},
  journal = {Science Progress},
  year = {2025},
  doi = {10.1177/00368504251387233}
}
Kostenlos starten →