Development and validation of an LC-MS/MS method for the detection of sodium pentachlorophenolate residues on cutting boards
Science Progress · 2024
DOI: 10.1177/00368504241300638 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Science Progress, 2024. Verfasst von Shicheng Liao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Analysis & Physical Testing Institute, Shenzhen Center for Disease Control and Prevention, Shenzhen, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Pentachlorophenol. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Guangdong Basic and Applied Basic Research Foundation, Shenzhen Science and Technology Program.
Abstract (Originalsprache)
Objectives
The objective of this study was to develop and validate an automated solid-phase extraction (SPE) coupled with ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the detection of sodium pentachlorophenolate (PCP-Na) residues on cutting boards. Given the potential hazards and environmental persistence of PCP-Na, a sensitive and reliable method is crucial for monitoring its residues in food contact materials to ensure consumer safety.
Methods
Wood shavings from cutting boards were extracted using 10% methanol in water, followed by purification using an automated SPE system. The eluent was concentrated, reconstituted, and analyzed by UPLC-MS/MS. An isotope-labeled internal standard was used to mitigate matrix effects, enhancing detection sensitivity. The method was validated by assessing linearity, limit of detection (LOD), limit of quantification (LOQ), recovery rates, and relative standard deviations (RSDs) across various concentration levels.
Results
The method demonstrated excellent linearity over a concentration range of 0 to 100 μg/L with a regression equation of Y = 1.035X−0.7771 and an R² of 0.9996. The LOD and LOQ were determined to be 0.4 and 1.0 μg/kg, respectively. Recovery rates ranged from 71.75% to 96.50% with RSDs between 5.19% and 16.66%. When applied to 30 market cutting board samples, PCP-Na residues were detected in 50% of the samples, with concentrations ranging from 0 to 83,990 µg/kg.
Conclusion
This study presents a robust UPLC-MS/MS method for the detection of PCP-Na on cutting boards, offering improved sensitivity and simplified sample preparation. The high detection rate in commercial samples underscores the need for stringent monitoring and regulatory measures to mitigate the exposure risk to consumers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chemical Analysis & Physical Testing Institute, Shenzhen Center for Disease Control and Prevention, Shenzhen, China.
- Shenzhen Center for Chronic Disease Control, Shenzhen, China.
ORCID-Profile: Zhuoying Zeng
Förderung
- Guangdong Basic and Applied Basic Research Foundation
- Shenzhen Science and Technology Program
Zitieren
APA
Liao, S., Xu, W., Jiang, J., Liu, H., & Zeng, Z. (2024). Development and validation of an LC-MS/MS method for the detection of sodium pentachlorophenolate residues on cutting boards. Science Progress. https://doi.org/10.1177/00368504241300638
Vancouver
Liao S, Xu W, Jiang J, Liu H, Zeng Z. Development and validation of an LC-MS/MS method for the detection of sodium pentachlorophenolate residues on cutting boards. Science Progress. 2024. doi:10.1177/00368504241300638
BibTeX
@article{Liao2024,
author = {Liao, Shicheng and Xu, Wanna and Jiang, Jie and Liu, Honghe and Zeng, Zhuoying},
title = {Development and validation of an LC-MS/MS method for the detection of sodium pentachlorophenolate residues on cutting boards},
journal = {Science Progress},
year = {2024},
doi = {10.1177/00368504241300638}
}
EUVIMED