EUVIMEDEUVIMED entdecken
Crossref

Pseudo-hypouricemia in four patients with lymphoma and one patient with breast cancer: Interference analysis and elimination

Guanqiao Shen, Qi Zhang, Shunchang Li iD

Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · 18.08.2026

DOI: 10.1177/00045632261478795 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, online erschienen am 18.08.2026. Verfasst von Guanqiao Shen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Shaoxing Second Hospital, Shaoxing, Zhejiang, China. Die Arbeit nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To investigate the interfering factors and correction methods in the determination of serum uric acid (UA) using the uricase method in patients with elevated immunoglobulin M (IgM). Materials and Methods In clinical practice, the UA levels of five patients with elevated IgM were measured using the Beckman AU5800 analyzer with its reagents or Zhongyuan reagents. The reaction curves were analyzed. Three methods dilution with normal saline, dilution with saturated saline, and polyethylene glycol 6000 (PEG 6000) precipitation were applied to eliminate interference. For comparison, UA was also measured using the Abbott Ci8200 analyzer with its reagents.

Results

The serum IgM levels for cases 1 to 5 were 12.39, 27.0, 12.09, 7.33, and 11.05 g/L, respectively. The initial UA results obtained with the Beckman AU5800 and its reagents were 48.4, 101.3, 96.6, 0.6, and 66.6 μmol/L. All five cases exhibited abnormal biochemical reaction curves. After treatment with normal saline, samples 1 and 5 yielded negative values, while after saturated saline treatment, sample 5 still showed a negative value and sample 1 showed an extremely low value, indicating incomplete correction of the interference. In contrast, the PEG precipitation method markedly improved the UA results, and the obtained values were comparable to those from the Abbott system.

Conclusion

The PEG precipitation method provides superior correction compared to dilution with normal or saturated saline and yields results that are closer to the patient’s true value.

Schlagwörter

Stichwörter der Autor:innen

IgMPEG 6000Uric aciduricase method

Autor:innen und Institutionen

  • Shaoxing Second Hospital, Shaoxing, Zhejiang, China.

ORCID-Profile: Shunchang Li

Zitieren

APA

Shen, G., Zhang, Q., & Li, S. (2026). Pseudo-hypouricemia in four patients with lymphoma and one patient with breast cancer: Interference analysis and elimination. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/00045632261478795

Vancouver

Shen G, Zhang Q, Li S. Pseudo-hypouricemia in four patients with lymphoma and one patient with breast cancer: Interference analysis and elimination. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 2026. doi:10.1177/00045632261478795

BibTeX
@article{Shen2026,
  author = {Shen, Guanqiao and Zhang, Qi and Li, Shunchang},
  title = {Pseudo-hypouricemia in four patients with lymphoma and one patient with breast cancer: Interference analysis and elimination},
  journal = {Annals of Clinical Biochemistry: International Journal of Laboratory Medicine},
  year = {2026},
  doi = {10.1177/00045632261478795}
}
Kostenlos starten →