EUVIMEDEUVIMED entdecken
Crossref

Comparison of Jaffe, Enzymatic, and Mass Spectrometric Methods for Creatinine Measurement in Protein-Positive and Hemoglobin-Positive Urine Samples

Gülsüm Abuşoğlu, Mohammad Ahmad Bik iD, Firdevs Sak, Duygu Eryavuz Onmaz, Ali Ünlü, Fatma Hümeyra Yerlikaya Aydemir, Sedat Abuşoğlu, Yasemin Coşkun Yavuz

Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · 07.07.2026

DOI: 10.1177/00045632261470633 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, online erschienen am 07.07.2026. Verfasst von Gülsüm Abuşoğlu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Laboratory Techniques, Vocational School of Health Sciences Medical Services and Techniques Institution, Selcuk University, Kon…. Gefördert von: Selçuk University Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate measurement of urine creatinine is essential for evaluating renal function. Although the Jaffe and enzymatic methods are routinely applied in clinical laboratories, various urinary compounds can interfere with these assays. This study investigated the effects of hemoglobin and protein positivity on creatinine measurement and partially validated a mass spectrometric (LC–MS/MS) procedure. Urine samples from 136 participants were categorized based on dipstick results into three groups: negative (n = 55), hemoglobin-positive (n = 51), and protein-positive (n = 30). Creatinine concentrations were measured using Jaffe and enzymatic methods on an Architect c16000 analyzer and by LC–MS/MS on an API 3200 system. The LC–MS/MS method demonstrated linearity between 3–350 mg/dL, intra- and inter-assay coefficients of variation of 3.2–3.8% and 1.9–2.9%, and bias values ranging from 1.1% to 18.2%. Correlations among LC–MS/MS, enzymatic, and Jaffe methods ranged from 0.981 to 0.998. Bland–Altman analysis showed mean absolute biases of 0.06 to 17.33 mg/dL (1.48–19.42%) in controls, 1.44 to 4.78 mg/dL (0.79–9.59%) in hemoglobin-positive samples, and 2.18 to 9.87 mg/dL (0.52–14.39%) in protein-positive samples. Regression analysis showed slopes closer to unity in hemoglobin- and protein-positive samples compared to controls, likely reflecting higher creatinine concentrations in these groups. Despite this apparent improvement, bias values increased, particularly in protein-positive samples. Both routine methods showed acceptable agreement with LC–MS/MS, while the enzymatic method demonstrated slightly closer agreement under these conditions. LC–MS/MS maintained highest analytical specificity. These findings highlight the importance of method selection for reliable interpretation of renal function, especially in patients presenting with hematuria or proteinuria.

Schlagwörter

Stichwörter der Autor:innen

Creatinineenzymatic methodsmass spectrometry

Autor:innen und Institutionen

  • Department of Medical Laboratory Techniques, Vocational School of Health Sciences Medical Services and Techniques Institution, Selcuk University, Konya, Turkey.
  • Department of Biochemistry, Faculty of Medicine, Selcuk University, Konya, Turkey.
  • Department of Biochemistry, Faculty of Medicine, Bandırma Onyedi Eylul University, Bandırma, Turkey.
  • Department of Nephrology, Faculty of Medicine, Selcuk University, Konya, Turkey.

ORCID-Profile: Mohammad Ahmad Bik

Förderung

  • Selçuk University Research Foundation

Zitieren

APA

Abuşoğlu, G., Ahmad Bik, M., Sak, F., Eryavuz Onmaz, D., Ünlü, A., Yerlikaya Aydemir, F. H., Abuşoğlu, S., & Coşkun Yavuz, Y. (2026). Comparison of Jaffe, Enzymatic, and Mass Spectrometric Methods for Creatinine Measurement in Protein-Positive and Hemoglobin-Positive Urine Samples. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/00045632261470633

Vancouver

Abuşoğlu G, Ahmad Bik M, Sak F, Eryavuz Onmaz D, Ünlü A, Yerlikaya Aydemir FH, et al. Comparison of Jaffe, Enzymatic, and Mass Spectrometric Methods for Creatinine Measurement in Protein-Positive and Hemoglobin-Positive Urine Samples. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 2026. doi:10.1177/00045632261470633

BibTeX
@article{Abuolu2026,
  author = {Abuşoğlu, Gülsüm and Ahmad Bik, Mohammad and Sak, Firdevs and Eryavuz Onmaz, Duygu and Ünlü, Ali and Yerlikaya Aydemir, Fatma Hümeyra and Abuşoğlu, Sedat and Coşkun Yavuz, Yasemin},
  title = {Comparison of Jaffe, Enzymatic, and Mass Spectrometric Methods for Creatinine Measurement in Protein-Positive and Hemoglobin-Positive Urine Samples},
  journal = {Annals of Clinical Biochemistry: International Journal of Laboratory Medicine},
  year = {2026},
  doi = {10.1177/00045632261470633}
}
Kostenlos starten →