EUVIMEDEUVIMED entdecken
Vergleichsstudie

Methods and reagent-lot comparisons by regression analysis: False positives

William A Sadler iD

Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · 2026-11 · 63 (6) · 494-496

DOI: 10.1177/00045632261454285 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, online erschienen am 26.05.2026. Verfasst von William A Sadler. Beteiligte Einrichtung: Nuclear Medicine Department, Christchurch Hospital, Christchurch, New Zealand. Hauptthemen laut MEDLINE: False Positive Reactions. Die Arbeit nennt 6 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The significance level specified for a statistical analysis indicates the expected false positive rate. Failure to confine false positives to their expected rates can lead to misleading conclusions and especially in studies investigating required sample sizes. A simulation study was used to investigate false positives associated with regression analysis.

Methods

Randomly generated X, Y pairs with zero underlying bias were subjected to Deming regression analysis. The design incorporated equal X, Y errors, unequal but parallel errors and non-parallel errors, each in combination with small (2:1), moderate (10:1) and large (2667:1) maximum:minimum range ratios. Bias (false positives in this context) was signified by failure of 95% confidence intervals (CIs) or, alternatively, the joint 95% slope, intercept confidence region (CR) to enclose target values.

Results

False positive rates assessed by CIs ranged from 6 to 10% and were clearly range ratio dependent, while those assessed by CRs were stable and very close to the expected 5% throughout.

Conclusions

CRs are distinctly more reliable than CIs in controlling false positive rates and should be the preferred option when using regression analysis in methods and reagent-lot comparisons. The computer program used to perform the study is freely available.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

False Positive ReactionsComputer SimulationIndicators and ReagentsRegression Analysis

Stichwörter der Autor:innen

Regressionbiasconfidence intervalfalse positivesjoint confidence regionmethods comparisonsreagent-lot comparisons

Substanzen

Indicators and Reagents

Autor:innen und Institutionen

  • Nuclear Medicine Department, Christchurch Hospital, Christchurch, New Zealand.

ORCID-Profile: William A Sadler

Zitieren

APA

Sadler, W. A. (2026). Methods and reagent-lot comparisons by regression analysis: False positives. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 63(6), 494-496. https://doi.org/10.1177/00045632261454285

Vancouver

Sadler WA. Methods and reagent-lot comparisons by regression analysis: False positives. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 2026;63(6):494-496. doi:10.1177/00045632261454285

BibTeX
@article{Sadler2026,
  author = {Sadler, William A},
  title = {Methods and reagent-lot comparisons by regression analysis: False positives},
  journal = {Annals of Clinical Biochemistry: International Journal of Laboratory Medicine},
  year = {2026},
  volume = {63},
  number = {6},
  pages = {494--496},
  doi = {10.1177/00045632261454285}
}
Kostenlos starten →