Effects of preanalytical factors on serum vitamin B12 test results

Tuba Batur iD, Ragıp Balahoroğlu, Hatice Karaoglan, Serap Sezer

Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · 2026-11 · 63 (6) · 476-482

DOI: 10.1177/00045632261453317 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, online erschienen am 16.05.2026. Verfasst von Tuba Batur und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Biochemistry, Mardin Training and Research Hospital, Mardin, Turkey. Hauptthemen laut MEDLINE: Vitamin B 12, Blood Specimen Collection. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Labotest Diagostic Systems.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

While conclusions regarding the effects of serum separator tubes on some laboratory tests have been reached in previous studies, the effects of these tubes on the B12 test have not been adequately investigated. This study aimed to determine the effects of the serum separator tube position after centrifugation on serum B12 test results. Materials and Methods Two blood samples were collected by venipuncture into 5-mL Pirmax serum separator tubes from each of the 30 volunteers. The effects of the tube position after centrifugation, gentle mixing 5–10 times, recentrifugation, and short-term (15 min) standing of the tubes in an upright position on serum B12 test results were examined in a step-by-step manner. The B12 analyses were performed in an ADVIA Centaur XPT autoanalyzer using a chemiluminescence method. Comparisons between the groups were evaluated for statistical and clinical significance.

Results

B12 levels were higher in the samples positioned horizontally than in the samples positioned vertically ( P < 0.001). The total effect of horizontal position and mixing was abolished by recentrifugation ( P = 0.091). The horizontal tube position and sample mixing led to an exceedance of the total allowable error limit.

Conclusions

The use of serum separator tubes may be associated with spuriously elevated serum B12 concentrations in the ADVIA Centaur XPT assay. The serum separator tubes should be kept upright in the post-centrifugation period prior to B12 analysis. We recommend recentrifugation if the tubes have been held in a horizontal position and/or the samples have been mixed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vitamin B 12Blood Specimen CollectionHumansCentrifugationFemaleMale

Stichwörter der Autor:innen

Vitamin B12interferenceposition of tubespreanalytical phaseserum separator tubes

Substanzen

Vitamin B 12

Autor:innen und Institutionen

  • Department of Medical Biochemistry, Mardin Training and Research Hospital, Mardin, Turkey.
  • Department of Medical Biochemistry, Beyhekim Training and Research Hospital, Konya, Turkey.
  • Department of Internal Medicine, Beyhekim Training and Research Hospital, Konya, Turkey.

ORCID-Profile: Tuba Batur

Förderung

  • Labotest Diagostic Systems

Zitieren

APA

Batur, T., Balahoroğlu, R., Karaoglan, H., & Sezer, S. (2026). Effects of preanalytical factors on serum vitamin B12 test results. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 63(6), 476-482. https://doi.org/10.1177/00045632261453317

Vancouver

Batur T, Balahoroğlu R, Karaoglan H, Sezer S. Effects of preanalytical factors on serum vitamin B12 test results. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 2026;63(6):476-482. doi:10.1177/00045632261453317

BibTeX
@article{Batur2026,
  author = {Batur, Tuba and Balahoroğlu, Ragıp and Karaoglan, Hatice and Sezer, Serap},
  title = {Effects of preanalytical factors on serum vitamin B12 test results},
  journal = {Annals of Clinical Biochemistry: International Journal of Laboratory Medicine},
  year = {2026},
  volume = {63},
  number = {6},
  pages = {476--482},
  doi = {10.1177/00045632261453317}
}
Kostenlos starten →