EUVIMEDEUVIMED entdecken
Crossref

Variability in SHBG assays and the effect thereof on calculated estimates of free testosterone

Joeri Walravens iD, Joanne Adaway iD, Tim Reyns, Nick Narinx iD, Jennifer Afrakoma Nyamaah, Leen Antonio, Jean-Marc Kaufman, Brian Keevil iD, Tom Fiers, Bruno Lapauw iD

Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · 2025

DOI: 10.1177/00045632251350676 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2025. Verfasst von Joeri Walravens und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine and Pediatrics, Ghent University & Department of Endocrinology, University Hospital Ghent, Ghent, Belgium. Hauptthemen laut MEDLINE: Testosterone, Sex Hormone-Binding Globulin. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: the Flemish FWO-TBM program, Fonds Wetenschappelijk Onderzoek.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Serum free testosterone is commonly used as a parameter to evaluate testosterone exposure and is mostly calculated using mathematical approximations. As the principal testosterone-binding protein, SHBG concentration is always included in such calculations. However, variability in SHBG measurements may affect reported SHBG levels and consequently free testosterone calculations. In this study, we re-evaluate the effects of SHBG assay choice and interlaboratory variability on calculated free testosterone (cFT).

Methods

Serum samples from 113 men and 106 women were collected. SHBG levels were measured using three different SHBG immunoassays (Roche, Abbott and Siemens). Testosterone levels were measured using LC-MS/MS. Afterwards, cFT was calculated using the Vermeulen formula and measured directly. SHBG concentrations, and derived cFT concentrations, from different assays were compared. To simulate interlaboratory SHBG variability, measured levels were modified by 15% after which cFT was recalculated using the Vermeulen, Ly, Sartorius and Södergard formulae. The proportions of diagnoses of hypogonadism or hyperandrogenism were compared.

Results

Assessed SHBG assays showed very good conformity. The largest difference was 7%, between the Abbott and Siemens assay. The difference in cFT levels was at most 3% between the Abbott and Siemens assay. Interlaboratory variability affected the proportion of diagnoses depending on the used formula.

Conclusions

Our results do not show large differences between SHBG assays and only minor effects on cFT levels. Therefore, SHBG assay choice is not expected to greatly influence clinical decision making. In contrast, interlaboratory variation in SHBG measurements and choice of formula might considerably affect cFT results and their interpretation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TestosteroneSex Hormone-Binding GlobulinHumansMaleFemaleMiddle AgedAdultImmunoassayHypogonadismTandem Mass SpectrometryChromatography, LiquidHyperandrogenismAged

Stichwörter der Autor:innen

SHBGfree testosteroneimmunoassay

Substanzen

TestosteroneSex Hormone-Binding GlobulinSHBG protein, human

Autor:innen und Institutionen

  • Department of Internal Medicine and Pediatrics, Ghent University & Department of Endocrinology, University Hospital Ghent, Ghent, Belgium.
  • Department of Clinical Biochemistry, Manchester University Hospital NHS Foundation Trust, Wythenshawe Hospital, Manchester, UK.
  • Department of Clinical Chemistry, University Hospital Ghent, Ghent, Belgium.
  • Laboratory of Clinical and Experimental Endocrinology, KU Leuven Leuven, Belgium.

ORCID-Profile: Joeri Walravens, Joanne Adaway, Nick Narinx, Brian Keevil, Bruno Lapauw

Förderung

  • the Flemish FWO-TBM program
  • Fonds Wetenschappelijk Onderzoek

Zitieren

APA

Walravens, J., Adaway, J., Reyns, T., Narinx, N., Nyamaah, J. A., Antonio, L., Kaufman, J. M., Keevil, B., Fiers, T., & Lapauw, B. (2025). Variability in SHBG assays and the effect thereof on calculated estimates of free testosterone. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/00045632251350676

Vancouver

Walravens J, Adaway J, Reyns T, Narinx N, Nyamaah JA, Antonio L, et al. Variability in SHBG assays and the effect thereof on calculated estimates of free testosterone. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 2025. doi:10.1177/00045632251350676

BibTeX
@article{Walravens2025,
  author = {Walravens, Joeri and Adaway, Joanne and Reyns, Tim and Narinx, Nick and Nyamaah, Jennifer Afrakoma and Antonio, Leen and Kaufman, Jean-Marc and Keevil, Brian and Fiers, Tom and Lapauw, Bruno},
  title = {Variability in SHBG assays and the effect thereof on calculated estimates of free testosterone},
  journal = {Annals of Clinical Biochemistry: International Journal of Laboratory Medicine},
  year = {2025},
  doi = {10.1177/00045632251350676}
}
Kostenlos starten →