Practical approaches to the detection of macrotroponin

Leo Lam iD, Campbell Kyle

Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · 2024

DOI: 10.1177/00045632231197301 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2024. Verfasst von Leo Lam und 1 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Pathology, LabPlus, Auckland City Hospital, Auckland, New Zealand. Hauptthemen laut MEDLINE: Troponin I, Immunoglobulins. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Macrotroponin is increasingly recognised as a cause of confusion in interpreting high-sensitivity cardiac troponin (hs-cTnI) results. In this study, we sought to evaluate two practical approaches to detecting macrotroponin. These two approaches are PEG precipitation and SVM (support vector machine) analysis to classify discrepancies between hs-cTn assays.

Method

Residual serum and heparin plasma specimens (n = 483) with initially elevated hs-cTnI from hospital and community laboratories were retested on multiple hs-cTn platforms before and after PEG precipitation and Protein A immunoglobulin depletion. SVM analysis was conducted to identify a linear equation that best discriminated specimens with macrotroponin using a combination of results from two different hs-cTn assays.

Findings

The diagnostic performance of PEG precipitation was carried out using Protein A immunoglobulin depletion as the reference comparator. When a cutoff residual activity after PEG precipitation of ≤ 20% was used, this threshold carried a high specificity of 92% (confidence interval 83–98%; n = 189) using the Siemens hs-cTnI Vista assay and 95% specificity (86%–98%; n = 242) using the Abbott hs-cTnI Architect assay. SVM analysis generated a linear equation identifying macrotroponin specimens from results obtained on two hs-cTn assays. This approach can be highly specific, comparable to PEG precipitation when certain assay combinations and concentrations are used.

Conclusion

We describe and identify practical alternatives to detecting macrotroponin. These approaches can be optimised for high specificity, reducing the need for more complex laboratory methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin IImmunoglobulinsHumansBiological AssayTroponin TBiomarkers

Stichwörter der Autor:innen

Troponinantibody interferencemacrotroponin

Substanzen

Troponin IImmunoglobulinsTroponin TBiomarkers

Autor:innen und Institutionen

  • Chemical Pathology, LabPlus, Auckland City Hospital, Auckland, New Zealand.
  • Biochemistry, Middlemore Hospital Laboratories, Auckland, New Zealand.
  • Biochemistry, Labtests, Auckland, New Zealand.

ORCID-Profile: Leo Lam

Zitieren

APA

Lam, L., & Kyle, C. (2024). Practical approaches to the detection of macrotroponin. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/00045632231197301

Vancouver

Lam L, Kyle C. Practical approaches to the detection of macrotroponin. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 2024. doi:10.1177/00045632231197301

BibTeX
@article{Lam2024,
  author = {Lam, Leo and Kyle, Campbell},
  title = {Practical approaches to the detection of macrotroponin},
  journal = {Annals of Clinical Biochemistry: International Journal of Laboratory Medicine},
  year = {2024},
  doi = {10.1177/00045632231197301}
}
Kostenlos starten →