EUVIMEDEUVIMED entdecken
Crossref

Comparison of plasma total carbon dioxide and standard hydrogen carbonate in a hospital laboratory setting

Rasmus Søgaard Hansen iD, Jesper Revsholm, Maria B Sandberg, Louise H Jørgensen, Mads Nybo iD

Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · 2023

DOI: 10.1177/00045632231152082 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2023. Verfasst von Rasmus Søgaard Hansen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Biochemistry, Odense University Hospital, Odense C, Denmark. Hauptthemen laut MEDLINE: Laboratories, Hospital, Acid-Base Imbalance. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Studies comparing venous total carbon dioxide (tCO 2 ) and standard hydrogen carbonate (HCO 3 – (P,st)) has shown diverse results, and it is debatable whether these two parameters can be used interchangeably for workup of acid–base disorders in a hospital setting.

Method

All patients with an HCO 3 – (P,st) requisition from any department at Odense University Hospital between 11th May 2021 and 1st June 2021 had tCO 2 and HCO 3 – (P,st) analysed simultaneously. TCO 2 was measured on Cobas® 8000, c702 module, while HCO 3 – (P,st) was calculated based on measurements on ABL835 Flex.

Results

From 1210 patients, mean (standard deviation (SD)) was 22.9 (3.7) mmol/L for tCO 2 and 22.5 (2.9) mmol/L for HCO 3 – (P,st). TCO 2 range was 10.1–42.3 mmol/L and 11.7–41.4 mmol/L for HCO 3 – (P,st). Linear regression showed that tCO 2 (mmol/L) = −2.90 + 1.15 × HCO 3 – (P,st) (mmol/L) with R 2 = 0.81. Bias (mean (SD) difference) between tCO 2 and HCO 3 – (P,st)) was 0.4 (1.7) mmol/L with a −5.0–9.6 mmol/L range. Limits of agreement was −2.90–3.70 mmol/L. Comparison of classification within, above or below reference interval for tCO 2 and HCO 3 – (P,st) showed that 984 samples (81%) retained their classification. Only one sample (0.1%) would be severely misclassified (outside the respective reference intervals) if HCO 3 – (P,st) was considered the gold standard. Of the samples investigated, 46.1% had a mean difference between tCO 2 and HCO 3 – (P,st) of 0–1 mmol/L and 30.3% had 1.1–2.0 mmol/L.

Conclusions

Our results indicate that venous tCO 2 and venous HCO 3 – (P,st) can be used interchangeably in a hospital setting for workup of acid–base disorders.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Laboratories, HospitalAcid-Base ImbalanceHumansBicarbonatesCarbon DioxideLinear Models

Stichwörter der Autor:innen

Carbon dioxideacid-base disordershospital laboratoryhydrogen carbonatesplasma

Substanzen

BicarbonatesCarbon Dioxide

Autor:innen und Institutionen

  • Department of Clinical Biochemistry, Odense University Hospital, Odense C, Denmark.

ORCID-Profile: Rasmus Søgaard Hansen, Mads Nybo

Zitieren

APA

Hansen, R. S., Revsholm, J., Sandberg, M. B., Jørgensen, L. H., & Nybo, M. (2023). Comparison of plasma total carbon dioxide and standard hydrogen carbonate in a hospital laboratory setting. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/00045632231152082

Vancouver

Hansen RS, Revsholm J, Sandberg MB, Jørgensen LH, Nybo M. Comparison of plasma total carbon dioxide and standard hydrogen carbonate in a hospital laboratory setting. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 2023. doi:10.1177/00045632231152082

BibTeX
@article{Hansen2023,
  author = {Hansen, Rasmus Søgaard and Revsholm, Jesper and Sandberg, Maria B and Jørgensen, Louise H and Nybo, Mads},
  title = {Comparison of plasma total carbon dioxide and standard hydrogen carbonate in a hospital laboratory setting},
  journal = {Annals of Clinical Biochemistry: International Journal of Laboratory Medicine},
  year = {2023},
  doi = {10.1177/00045632231152082}
}