EUVIMEDEUVIMED entdecken
Crossref

Multi-Parameter Wavelength Characterization of Array Spectrometers Under Near-Limit Sampling Conditions

Du Bo, Liu Liying iD, Wu Dongli, Wu Zhifeng iD, Zheng Feng iD, Liu Cong iD, Li Ning, Zhang Jing, Zhang Shihao

Applied Spectroscopy · 01.07.2026

DOI: 10.1177/00037028261468369 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Spectroscopy, online erschienen am 01.07.2026. Verfasst von Du Bo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Meteorological Observation Centre of China Meteorological Administration, Beijing, 100081, China. Die Arbeit nennt 14 Literaturangaben. Gefördert von: Study on the characteristics evaluation of spectrometer in vegetation ecosystems observation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate wavelength characterization is essential for high-precision spectral measurements, particularly in applications such as solar-induced chlorophyll fluorescence (SIF) retrieval, where weak spectral signals are highly sensitive to instrument performance. In array spectrometers, characteristic wavelengths can be defined by peak, center, or centroid positions, whereas spectral resolution is commonly represented by full width at half-maximum (FWHM) or equivalent rectangular width (ERW). This study systematically investigates the influence of sampling conditions on wavelength characterization using a crossed Czerny–Turner array spectrometer operating over the 650–800 nm spectral range. The concept of sampling ratio is employed to define near-limit sampling conditions, in which monochromatic spectral peaks are represented by only 2–5 detector pixels. Experimental results show that the spectrometer predominantly operates within this regime. Under these conditions, significant discrepancies arise among different characteristic wavelength definitions owing to the combined effects of discrete sampling and spectral peak shape. Peak-based wavelength estimation is primarily affected by local sampling variations, whereas centroid-based definitions are more sensitive to energy distribution and peak asymmetry. Furthermore, a systematic divergence between ERW and FWHM demonstrates that spectral resolution metrics depend not only on geometric peak width but also on spectral energy distribution, particularly under non-ideal imaging conditions. These results show that wavelength characterization should be regarded as a coupled problem involving sampling conditions, spectral peak representation, and resolution metrics rather than as independent parameters. The proposed multi-parameter characterization approach establishes a practical framework by clarifying the relationships among sampling ratio, characteristic wavelength definitions, and spectral resolution, introducing two deviation metrics to quantify inconsistencies among wavelength definitions, and revealing the complementary physical significance of FWHM and ERW from geometric and energy-distribution perspectives. This approach provides a physically interpretable basis for wavelength calibration, spectral resolution evaluation, and performance assessment of array spectrometers operating under near-limit sampling conditions.

Schlagwörter

Stichwörter der Autor:innen

Wavelength characterizationarray spectrometernear-limit samplingspectral resolutionwavelength calibration accuracy

Autor:innen und Institutionen

  • Meteorological Observation Centre of China Meteorological Administration, Beijing, 100081, China.
  • Key Laboratory of Ecosystem Carbon Source and Sink, China Meteorological Administration (ECSS-CMA), Nanjing University of Information Science and Technology, Nanjing, Jiangsu, 210044, China.
  • Aerospace New Sky Technology Co., Ltd, Wuxi, Jiangsu, 214127, China.
  • Division of Optics, National Institute of Metrology (NIM), Beijing, 100029, China.

ORCID-Profile: Liu Liying, Wu Zhifeng, Zheng Feng, Liu Cong

Förderung

  • Study on the characteristics evaluation of spectrometer in vegetation ecosystems observation

Zitieren

APA

Bo, D., Liying, L., Dongli, W., Zhifeng, W., Feng, Z., Cong, L., Ning, L., Jing, Z., & Shihao, Z. (2026). Multi-Parameter Wavelength Characterization of Array Spectrometers Under Near-Limit Sampling Conditions. Applied Spectroscopy. https://doi.org/10.1177/00037028261468369

Vancouver

Bo D, Liying L, Dongli W, Zhifeng W, Feng Z, Cong L, et al. Multi-Parameter Wavelength Characterization of Array Spectrometers Under Near-Limit Sampling Conditions. Applied Spectroscopy. 2026. doi:10.1177/00037028261468369

BibTeX
@article{Bo2026,
  author = {Bo, Du and Liying, Liu and Dongli, Wu and Zhifeng, Wu and Feng, Zheng and Cong, Liu and Ning, Li and Jing, Zhang and Shihao, Zhang},
  title = {Multi-Parameter Wavelength Characterization of Array Spectrometers Under Near-Limit Sampling Conditions},
  journal = {Applied Spectroscopy},
  year = {2026},
  doi = {10.1177/00037028261468369}
}
Kostenlos starten →