Fractional–Rational Calibration for Laser-Induced Breakdown Spectroscopy (LIBS) Analysis of Steels with High Matrix Variability
Applied Spectroscopy · 2026-08 · 80 (8) · 917-929
DOI: 10.1177/00037028261456320 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Spectroscopy, online erschienen am 07.07.2026. Verfasst von Vasilii Kiris und 1 weiteren Autor:innen. Beteiligte Einrichtung: B.I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, Minsk, Belarus. Die Arbeit nennt 29 Literaturangaben. Gefördert von: State Program of Scientific Research of the Republic of Belarus 'Photonics and Electronics for Innovations.
Abstract (Originalsprache)
The results of an original calibration methodology that accounts for interelement influences in the analysis of alloyed steels using laser-induced breakdown spectroscopy (LIBS) are presented. The results were obtained from a dataset of spectra provided for the regression competition at the LIBS 2022 conference and available online. The dataset includes spectra from 41 steel samples with known concentrations of major alloying elements (chromium, nickel, manganese, molybdenum, carbon, silicon, copper) and 15 samples with unknown compositions for model validation. The concentration of alloying elements varies over a wide range, with iron content ranging from 98% to 41%. To reduce spectral line position instability, we applied a preprocessing method that maximizes the correlation of each spectrum with the first spectrum in the dataset. The implementation of the developed calibration methodology led to an improvement in the root mean square error of the analysis, with reduction factors ranging from two (for nickel and molybdenum) to five (for manganese and chromium) when compared to classical calibration.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- B.I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, Minsk, Belarus.
ORCID-Profile: Vasilii Kiris, Mikhail Belkov
Förderung
- State Program of Scientific Research of the Republic of Belarus 'Photonics and Electronics for Innovations
Zitieren
APA
Kiris, V., & Belkov, M. (2026). Fractional–Rational Calibration for Laser-Induced Breakdown Spectroscopy (LIBS) Analysis of Steels with High Matrix Variability. Applied Spectroscopy, 80(8), 917-929. https://doi.org/10.1177/00037028261456320
Vancouver
Kiris V, Belkov M. Fractional–Rational Calibration for Laser-Induced Breakdown Spectroscopy (LIBS) Analysis of Steels with High Matrix Variability. Applied Spectroscopy. 2026;80(8):917-929. doi:10.1177/00037028261456320
BibTeX
@article{Kiris2026,
author = {Kiris, Vasilii and Belkov, Mikhail},
title = {Fractional–Rational Calibration for Laser-Induced Breakdown Spectroscopy (LIBS) Analysis of Steels with High Matrix Variability},
journal = {Applied Spectroscopy},
year = {2026},
volume = {80},
number = {8},
pages = {917--929},
doi = {10.1177/00037028261456320}
}