EUVIMEDEUVIMED entdecken
Crossref

High-Sensitivity Detection of Acetone in Human Breath Using Near-Infrared Continuous Wave Cavity Ring-Down Spectroscopy

Eshtar Aluauee iD, James Bounds iD, Alexandre Kolomenskii iD, Hans Schuessler, Liam Fernyhough iD

Applied Spectroscopy · 26.05.2026

DOI: 10.1177/00037028261454394 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Spectroscopy, online erschienen am 26.05.2026. Verfasst von Eshtar Aluauee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Scientific Research Commission, Baghdad, Iraq. Die Arbeit nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study utilizes continuous wave cavity ring-down spectroscopy (CW-CRDS) at a wavelength approximately 1672 nm to detect acetone and methane in exhaled human breath. We employed a commercial distributed feedback diode laser (DFB), which delivered approximately 4 mW of power across a tuning range of 3.5 nm to measure acetone and methane concentrations in exhaled human breath. A detection limit of about 10.5 parts per billion (ppb) was demonstrated. Samples were collected from two distinct population locations, 23 individuals from Doha, Qatar, and 19 volunteers from College Station, Texas. The content of multiple gas mixture components was determined. The developed method for retroactive determination of the laser tuning eliminated the need for online wavelength determination. Simultaneous measurements of acetone and methane in exhaled breath can assist in diagnosing and monitoring diabetes and in assessing metabolic profiles of individuals using this noninvasive technique.

Schlagwörter

Stichwörter der Autor:innen

CW-CRDSContinuous wave cavity ring-down spectroscopyNIR spectroscopyacetone biomarkerdetection limitnear-infrared spectroscopy

Autor:innen und Institutionen

  • Scientific Research Commission, Baghdad, Iraq.
  • Department of Physics and Astronomy, Texas A&M University, College Station, Texas, USA.
  • Department of Medical Education, Weill Cornell Medicine, Doha, Qatar.

ORCID-Profile: Eshtar Aluauee, James Bounds, Alexandre Kolomenskii, Liam Fernyhough

Zitieren

APA

Aluauee, E., Bounds, J., Kolomenskii, A., Schuessler, H., & Fernyhough, L. (2026). High-Sensitivity Detection of Acetone in Human Breath Using Near-Infrared Continuous Wave Cavity Ring-Down Spectroscopy. Applied Spectroscopy. https://doi.org/10.1177/00037028261454394

Vancouver

Aluauee E, Bounds J, Kolomenskii A, Schuessler H, Fernyhough L. High-Sensitivity Detection of Acetone in Human Breath Using Near-Infrared Continuous Wave Cavity Ring-Down Spectroscopy. Applied Spectroscopy. 2026. doi:10.1177/00037028261454394

BibTeX
@article{Aluauee2026,
  author = {Aluauee, Eshtar and Bounds, James and Kolomenskii, Alexandre and Schuessler, Hans and Fernyhough, Liam},
  title = {High-Sensitivity Detection of Acetone in Human Breath Using Near-Infrared Continuous Wave Cavity Ring-Down Spectroscopy},
  journal = {Applied Spectroscopy},
  year = {2026},
  doi = {10.1177/00037028261454394}
}