Fluorescence and Colorimetric Dual-Readout Detection of Tetracycline Using Leucine-Conjugated Iron Oxide Quantum Dots
Applied Spectroscopy · 2024-11 · 78 (11) · 1191-1202
DOI: 10.1177/00037028241279464 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Spectroscopy, online erschienen am 23.09.2024. Verfasst von Sri Sudewi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, Faculty of Mathematics and Natural Science, Universitas Sam Ratulangi, Manado, Indonesia. Hauptthemen laut MEDLINE: Quantum Dots, Colorimetry, Tetracycline, Spectrometry, Fluorescence. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Kaohsiung Medical University, National Science and Technology Council.
Abstract (Originalsprache)
This study developed a dual-readout system utilizing fluorescence and colorimetry based on iron oxide quantum dots (IO-QDs) for detecting tetracycline (TCy). IO-QDs were synthesized within 6 h using L-leucine as a surface modifier, achieving a more efficient route. Upon interaction with TCy, IO-QDs exhibited a significant decrease in fluorescence response and observable color changes, while fluorescence lifetime remained consistent regardless of TCy presence. Moreover, IO-QDs’ fluorescence response remained stable across various temperatures. The Förster resonance energy transfer distance of less than 2 nm and a quenching constant of 2.90 × 10 12 M –1 s –1 indicated static quenching in the presence of TCy. Additionally, significant changes in observed and corrected fluorescence efficiency suggested the involvement of the inner filter effect in the fluorescence quenching of IO-QDs. The synthesized IO-QDs were then utilized for selective and rapid fluorescence-based TCy detection, showing a linear range of 0.5 to 80 μM. Simultaneously, a colorimetric method for TCy detection was established, demonstrating a good linear relationship within the range of 0.5 to 20 μM. The detection limits for TCy were determined as 0.539 and 0.329 μM using fluorescence and colorimetric approaches, respectively. Furthermore, IO-QDs were applied to detect real samples, and the dual-readout probe exhibited satisfactory recoveries, confirming the practical reliability of the developed method for analyzing milk and drinking water samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pharmacy, Faculty of Mathematics and Natural Science, Universitas Sam Ratulangi, Manado, Indonesia.
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung.
- Research Center for Chemistry, National Research and Innovation Agency (BRIN), Tangerang, Indonesia.
- Department of Chemistry Education, Universitas Serambi Mekkah, Banda Aceh, Indonesia.
- Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung.
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung.
ORCID-Profile: Akhtar Rasool, Genin Gary Huang
Förderung
- Kaohsiung Medical University
- National Science and Technology Council
Zitieren
APA
Sudewi, S., Sashank, P. V. S., Rasool, A., Ullah, N., Zulfajri, M., Chen, H. Y., & Huang, G. G. (2024). Fluorescence and Colorimetric Dual-Readout Detection of Tetracycline Using Leucine-Conjugated Iron Oxide Quantum Dots. Applied Spectroscopy, 78(11), 1191-1202. https://doi.org/10.1177/00037028241279464
Vancouver
Sudewi S, Sashank PVS, Rasool A, Ullah N, Zulfajri M, Chen HY, et al. Fluorescence and Colorimetric Dual-Readout Detection of Tetracycline Using Leucine-Conjugated Iron Oxide Quantum Dots. Applied Spectroscopy. 2024;78(11):1191-1202. doi:10.1177/00037028241279464
BibTeX
@article{Sudewi2024,
author = {Sudewi, Sri and Sashank, Penki Venkata Sai and Rasool, Akhtar and Ullah, Najeeb and Zulfajri, Muhammad and Chen, Hsuan-Ying and Huang, Genin Gary},
title = {Fluorescence and Colorimetric Dual-Readout Detection of Tetracycline Using Leucine-Conjugated Iron Oxide Quantum Dots},
journal = {Applied Spectroscopy},
year = {2024},
volume = {78},
number = {11},
pages = {1191--1202},
doi = {10.1177/00037028241279464}
}
EUVIMED