Fachartikel in der Zeitschrift Annals of Otology, Rhinology & Laryngology, 2024. Verfasst von Ishwor Gautam und 4 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering, Department of Biomedical Engineering, The University of Akron, Akron, OH, USA. Hauptthemen laut MEDLINE: Cochlear Implantation, Models, Anatomic, Printing, Three-Dimensional, Feasibility Studies. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
Objective
Creation of a novel 3D-printed physical cochlear model that demonstrated the feasibility of creating the model, and impact of a Graphical User Interface (GUI) system on training insertion metrics. Study Design: Feasibility study with a pilot prospective data collection.
Setting
Tertiary academic center.
Methods
The study was IRB exempt. Five resident trainees (PGY1-PGY5) practiced electrode insertions in cadaveric temporal bones before using the simulator. Nine students were educated on how to hold the electrodes and position them, and then allowed to use the simulator. All trainees were instructed that slower insertions were favorable. One cochlear implant (CI) surgeon used the simulator. The GUI captured the real video feed, but also provided distance, trajectory, and velocity measurements. The program is designed to plot the real-time depth of insertion and speed of insertion of the electrode; the user is also provided real-time occurrence of any kinks and back-outs.
Results
A total of 14 trainees and 1 CI surgeon inserted the electrode at least 5 times without the use of the GUI (before) and then at least 5 times with the use of the GUI (after). Average Speed before and after (100.84 and 53.23 mm/s); Average minimum speed before and after (59.34 and 9.65 mm/s); and Average maximum speed before and after (416 and 285.81 mm/s). Statistically significant improvements were noted in all the measured speeds of insertion ( P < .001). The other variables improved but not to a statistical significance.
Conclusions
Real-time training using the 3D-printed model and GUI for cochlear implantation can help improve surgical resident training and comfort levels with electrode insertion for surgical trainees. The advantage of this model is that surgeons/trainees can use it as many times as they like, as the whole set-up is easy, economical, and reusable. The real time graphical user interface enhances training and retention of the practiced skills.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering, Department of Biomedical Engineering, The University of Akron, Akron, OH, USA.
- Department of Otolaryngology, Mercy Bon Secours, Youngstown, OH, USA.
- Department of Computer Science, Ashland University, Ashland, OH, USA.
- Northeast Ohio Medical University, Rootstown, OH, USA.
ORCID-Profile: Anita Jeyakumar
Zitieren
APA
Gautam, I., Shaw, A., Brickman, D., Mahajan, A., & Jeyakumar, A. (2024). Creation of a Prototype Cochlear Training Model. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/00034894241238868
Vancouver
Gautam I, Shaw A, Brickman D, Mahajan A, Jeyakumar A. Creation of a Prototype Cochlear Training Model. Annals of Otology, Rhinology & Laryngology. 2024. doi:10.1177/00034894241238868
BibTeX
@article{Gautam2024,
author = {Gautam, Ishwor and Shaw, Avi and Brickman, Dhiren and Mahajan, Ajay and Jeyakumar, Anita},
title = {Creation of a Prototype Cochlear Training Model},
journal = {Annals of Otology, Rhinology & Laryngology},
year = {2024},
doi = {10.1177/00034894241238868}
}
EUVIMED