Safety and Feasibility of Steroid-Eluting Stent as a Bolster in Endoscopic Anterior Skull Base Reconstruction
Annals of Otology, Rhinology & Laryngology · 2024
DOI: 10.1177/00034894231181178 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Otology, Rhinology & Laryngology, 2024. Verfasst von John B Finlay und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Head and Neck Surgery and Communication Sciences, Duke University School of Medicine, Durham, NC, USA. Hauptthemen laut MEDLINE: Plastic Surgery Procedures, Drug-Eluting Stents. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS.
Abstract (Originalsprache)
Background
With a rising incidence of cerebrospinal fluid (CSF) leaks, endoscopic endonasal CSF leak repair is increasingly performed. Current approaches utilize a variety of materials including free mucosal grafts and vascularized flaps, but post-op leaks continue to be reported. Steroid-eluting bioabsorbable stents (SES) are used during functional endoscopic sinus surgery for chronic rhinosinusitis to reduce inflammation and scarring while maintaining patency of sinus ostia.
Objective
The aim of this study is to assess the feasibility of SES as a graft/flap bolster for endoscopic endonasal CSF leak repair.
Methods
This is a retrospective review of patients undergoing endoscopic endonasal CSF leak repair with SES placed as part of the bolster technique at a tertiary care center between January 2019 and May 2022. Age, sex, BMI, comorbid idiopathic intracranial hypertension, pathology, location of CSF leak, intraoperative CSF leak flow, reconstruction type, and presence of post-op CSF leak were recorded.
Results
Twelve patients (mean age 52, median BMI 30.9, 58% female) had SES placement as part of the bolster technique. The most common pathology was meningoencephalocele (75%). Reconstruction was performed with either a free mucosal graft (6), or a flap (6). No post-op CSF leaks occurred at a reconstruction site with a stent, and no known complications were reported. All sinusotomies were patent at the last follow-up visit.
Conclusions
SES placement as an adjunct to graft and/or flap bolster appears to be safe and feasible during anterior skull base reconstruction and CSF leak repair providing longer term structural support and preserving sinus drainage patency.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Head and Neck Surgery and Communication Sciences, Duke University School of Medicine, Durham, NC, USA.
- Medical Scientist Training Program, Duke University School of Medicine, Durham, NC, USA.
- Department of Neurosurgery, Duke University School of Medicine, Durham, NC, USA.
- Duke Skull Base Center, Duke University School of Medicine, Durham, NC, USA.
- Department of Neurobiology, Duke University School of Medicine, Durham, NC, USA.
ORCID-Profile: John B Finlay, Khalil Issa
Förderung
- NIGMS NIH HHS
Zitieren
APA
Finlay, J. B., Issa, K., Ackall, F., Zomorodi, A., Codd, P., Jang, D. W., Goldstein, B. J., & Abi Hachem, R. (2024). Safety and Feasibility of Steroid-Eluting Stent as a Bolster in Endoscopic Anterior Skull Base Reconstruction. Annals of Otology, Rhinology & Laryngology. https://doi.org/10.1177/00034894231181178
Vancouver
Finlay JB, Issa K, Ackall F, Zomorodi A, Codd P, Jang DW, et al. Safety and Feasibility of Steroid-Eluting Stent as a Bolster in Endoscopic Anterior Skull Base Reconstruction. Annals of Otology, Rhinology & Laryngology. 2024. doi:10.1177/00034894231181178
BibTeX
@article{Finlay2024,
author = {Finlay, John B and Issa, Khalil and Ackall, Feras and Zomorodi, Ali and Codd, Patrick and Jang, David W and Goldstein, Bradley J and Abi Hachem, Ralph},
title = {Safety and Feasibility of Steroid-Eluting Stent as a Bolster in Endoscopic Anterior Skull Base Reconstruction},
journal = {Annals of Otology, Rhinology & Laryngology},
year = {2024},
doi = {10.1177/00034894231181178}
}
EUVIMED