EUVIMEDEUVIMED entdecken
Crossref

Placement of Intracranial Pressure Monitors by Non-neurosurgeons: A Follow-Up Study

Dania Jumpa, Kelly Lightwine, Elizabeth Ablah, Hayrettin Okut, Raymond Grundmeyer, James M Haan

The American Surgeon™ · 2024

DOI: 10.1177/00031348231220575 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The American Surgeon™, 2024. Verfasst von Dania Jumpa und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Population Health, School of Medicine, The University of Kansas, Wichita, KS, USA. Hauptthemen laut MEDLINE: Neurosurgeons, Craniocerebral Trauma. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Some research suggests that physicians who are not neurosurgeons can safely place intracranial pressure (ICP) monitors. The purpose of this study was to compare intracranial pressure monitor placement complications between neurosurgeons, trauma physicians, and general surgery residents. We hypothesized that with appropriate training, general residents can safely place ICP monitors.

Methods

A 10-year retrospective chart review of all trauma patients that required ICP monitor placement between January 1, 2012, and December 31, 2021, was conducted. Comparisons were made between treatment groups.

Results

During the study period, 194 patients required ICP monitor placement. General surgery residents placed 94.3% of ICP monitors, 3.6% were placed by attending trauma physicians, and 2.1% by neurosurgeons. No ICP monitors were placed by attending trauma physicians or neurosurgeons between 2015 and 2018. Overall, minor complications during ICP monitor placement included device malfunction (2.7%) and inaccurate readings (.5%). There were no major complications during ICP monitor placement. Post-ICP monitor placement complications included one patient who experienced a central nervous system infection (.5%) and three patients who had mechanical problems (1.5%). No complications occurred among the neurosurgeon or attending trauma physician treatment groups.

Conclusion

Most intracranial pressure monitors in our study sample were safely placed by surgical residents. Based on our study findings and considering the shortage and downtrend of neurosurgery specialists, ICP bolt placement needs to become a core clinical skill in surgical resident programs across the United States.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeurosurgeonsCraniocerebral TraumaHumansUnited StatesFollow-Up StudiesRetrospective StudiesIntracranial PressureMonitoring, Physiologic

Stichwörter der Autor:innen

boltintracranial pressure monitornon-neurosurgeonstraumatic brain injury

Autor:innen und Institutionen

  • Department of Population Health, School of Medicine, The University of Kansas, Wichita, KS, USA.
  • Department of Trauma Services, Ascension Via Christi St Francis, Wichita, KS, USA.
  • Department of Neurosurgery, Ascension Via Christi St Francis, Wichita, KS, USA.

Zitieren

APA

Jumpa, D., Lightwine, K., Ablah, E., Okut, H., Grundmeyer, R., & Haan, J. M. (2024). Placement of Intracranial Pressure Monitors by Non-neurosurgeons: A Follow-Up Study. The American Surgeon™. https://doi.org/10.1177/00031348231220575

Vancouver

Jumpa D, Lightwine K, Ablah E, Okut H, Grundmeyer R, Haan JM. Placement of Intracranial Pressure Monitors by Non-neurosurgeons: A Follow-Up Study. The American Surgeon™. 2024. doi:10.1177/00031348231220575

BibTeX
@article{Jumpa2024,
  author = {Jumpa, Dania and Lightwine, Kelly and Ablah, Elizabeth and Okut, Hayrettin and Grundmeyer, Raymond and Haan, James M},
  title = {Placement of Intracranial Pressure Monitors by Non-neurosurgeons: A Follow-Up Study},
  journal = {The American Surgeon™},
  year = {2024},
  doi = {10.1177/00031348231220575}
}