EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Description and Evaluation of a Visual Acuity Assessment Paradigm Based on Spatial Frequency-Modulated Form Discrimination

Jonathan Lansey, Indrani Sirivella, Rahul Negi, Shaun R Patel, Shrikant R Bharadwaj

Translational Vision Science & Technology · 2026

DOI: 10.1167/tvst.15.9.15 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2026. Verfasst von Jonathan Lansey und 4 weiteren Autor:innen. Beteiligte Einrichtung: REACT Neuro, Inc., Cambridge, MA, USA. Hauptthemen laut MEDLINE: Visual Acuity, Vision Tests, Form Perception, Discrimination, Psychological. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To describe and evaluate a visual acuity assessment paradigm based on spatial frequency-modulated form discrimination for induced and disease-driven vision loss.

Methods

The Patterned-Optotype-in-Noise Task (POINT) consisted of arrow-shaped random noise patterns, each with a 1/f2 amplitude spectrum overlaid on a low-pass filtered background. Stimulus difficulty varied logarithmically across 22 levels by adjusting the background cutoff spatial frequency, relative to foreground. Monocular acuity was measured for POINT stimuli and letter optotypes in 20 adults (21-46 years) with 0-4D of induced blur and in 50 patients (9-77 years) with vision impairment from ocular pathologies/uncorrected refractive error.

Results

The POINT demonstrated systematic loss in visual acuity with induced optical blur and eye pathologies, like the standard letter acuity test (P < 0.001). The losses with induced blur in the POINT followed standard Fourier optics predictions of spatial-frequency discrimination between the background and foreground pattern. The test-retest repeatability of POINT was also comparable to letter acuity testing (mean difference ± 95% limits of agreement: +0.04 units ± 0.2 units), but with limited agreement in the acuity measures obtained between the two tests.

Conclusions

The POINT is a reliable technique for estimating visual acuity with induced and disease-driven vision loss. However, caution should be exercised when directly comparing these outcomes to standard letter acuity tests owing to fundamental differences in stimulus construction and task requirements. Translational Relevance: The POINT offers a physiologically and theoretically grounded complement to standard assessment of visual acuity in clinical, research and public eye health settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuityVision TestsForm PerceptionDiscrimination, PsychologicalVision DisordersHumansMiddle AgedAdultFemaleAdolescentAgedMaleChildYoung AdultReproducibility of ResultsPhotic Stimulation

Autor:innen und Institutionen

  • REACT Neuro, Inc., Cambridge, MA, USA.
  • Prof. Brien Holden Eye Research Centre, L V Prasad Eye Institute, Hyderabad, India.
  • Centre for Technology Innovation, L V Prasad Eye Institute, Hyderabad, India.
  • Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.

Zitieren

APA

Lansey, J., Sirivella, I., Negi, R., Patel, S. R., & Bharadwaj, S. R. (2026). Description and Evaluation of a Visual Acuity Assessment Paradigm Based on Spatial Frequency-Modulated Form Discrimination. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.15.9.15

Vancouver

Lansey J, Sirivella I, Negi R, Patel SR, Bharadwaj SR. Description and Evaluation of a Visual Acuity Assessment Paradigm Based on Spatial Frequency-Modulated Form Discrimination. Translational Vision Science & Technology. 2026. doi:10.1167/tvst.15.9.15

BibTeX
@article{Lansey2026,
  author = {Lansey, Jonathan and Sirivella, Indrani and Negi, Rahul and Patel, Shaun R and Bharadwaj, Shrikant R},
  title = {Description and Evaluation of a Visual Acuity Assessment Paradigm Based on Spatial Frequency-Modulated Form Discrimination},
  journal = {Translational Vision Science & Technology},
  year = {2026},
  doi = {10.1167/tvst.15.9.15}
}
Kostenlos starten →