Enhanced Visualization of Choroidal Defects in Focal Choroidal Excavation With Near-Infrared Autofluorescence: Multimodal Imaging Study
Translational Vision Science & Technology · 2026
DOI: 10.1167/tvst.15.9.10 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Translational Vision Science & Technology, 2026. Verfasst von Yuta Nakanishi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Multimodal Imaging, Fluorescein Angiography, Choroid. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To compare the spatial concordance of autofluorescence abnormalities on near-infrared fundus autofluorescence (NIRAF) and short-wavelength fundus autofluorescence (SWAF) with the area of focal choroidal excavation (FCE) defined on en face optical coherence tomography (OCT).
Methods
In this retrospective cross-sectional observational study, a 6 × 6-mm en face swept-source OCT image centered on the fovea was used to define the structural FCE area on a choroidal slab. After image registration, areas of abnormal autofluorescence, including hypoautofluorescence and hyperautofluorescence, were delineated on SWAF and NIRAF. Spatial concordance between the en face OCT-defined FCE area and the abnormal autofluorescence areas was evaluated using the Dice similarity coefficient (DSC).
Results
Twenty eyes of 20 patients with conforming-type FCE were included. The mean FCE area was 0.708 ± 0.571 mm2 on en face OCT, 1.174 ± 1.196 mm2 on NIRAF (P = 0.534 vs. en face OCT), and 0.152 ± 0.203 mm2 on SWAF (P < 0.001 vs. en face OCT). Spatial concordance with en face OCT was significantly greater for NIRAF (DSC, 0.654 ± 0.187) than for SWAF (DSC, 0.160 ± 0.214; P < 0.001). NIRAF detected abnormal autofluorescence corresponding to the FCE area in all eyes, whereas SWAF failed to detect any abnormality in six eyes (30%).
Conclusions
FCE-associated abnormalities on NIRAF showed greater spatial concordance with the FCE area defined on en face OCT than those on SWAF. Translational Relevance: NIRAF offers a reproducible, noninvasive means of spatially mapping melanin-associated autofluorescence abnormalities, supporting more precise multimodal characterization of FCE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Zitieren
APA
Nakanishi, Y., Kadomoto, S., Sakamoto, T., Kogo, T., Muraoka, Y., Hata, M., & Tsujikawa, A. (2026). Enhanced Visualization of Choroidal Defects in Focal Choroidal Excavation With Near-Infrared Autofluorescence: Multimodal Imaging Study. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.15.9.10
Vancouver
Nakanishi Y, Kadomoto S, Sakamoto T, Kogo T, Muraoka Y, Hata M, et al. Enhanced Visualization of Choroidal Defects in Focal Choroidal Excavation With Near-Infrared Autofluorescence: Multimodal Imaging Study. Translational Vision Science & Technology. 2026. doi:10.1167/tvst.15.9.10
BibTeX
@article{Nakanishi2026,
author = {Nakanishi, Yuta and Kadomoto, Shin and Sakamoto, Tomoaki and Kogo, Takahiro and Muraoka, Yuki and Hata, Masayuki and Tsujikawa, Akitaka},
title = {Enhanced Visualization of Choroidal Defects in Focal Choroidal Excavation With Near-Infrared Autofluorescence: Multimodal Imaging Study},
journal = {Translational Vision Science & Technology},
year = {2026},
doi = {10.1167/tvst.15.9.10}
}