Repeatability of Foveal Sensitivity Measured Using Adaptive Optics Microperimetry
Translational Vision Science & Technology · 05.08.2026 · 15 (8) · 3
DOI: 10.1167/tvst.15.8.3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 05.08.2026. Verfasst von Nivedhitha Govindasamy und 3 weiteren Autor:innen. Beteiligte Einrichtung: Bioengineering Graduate Group, University of Pennsylvania, Philadelphia, PA, USA. Hauptthemen laut MEDLINE: Fovea Centralis, Visual Field Tests, Visual Fields, Optics and Photonics. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
To assess the within and between-session repeatability of foveal sensitivity measurements using adaptive optics (AO) microperimetry.
Methods
Five normal-sighted participants underwent AO microperimetry testing (550-nm circular stimulus) at the preferred retinal locus across two sessions (2 months ± 2 weeks). Two psychophysical paradigms were used: quick estimation of threshold (QUEST) and method of constant stimuli (MOCS). Each paradigm employed both 1.05-arcmin2 and 30.4-arcmin2 stimulus sizes; stimuli were not stabilized in real time. Trial-by-trial responses were fit with a logistic psychometric function to obtain thresholds at a criterion of 78% seen. Thresholds were converted to sensitivity. Statistical comparisons were performed using paired-sample t-tests.
Results
Sensitivities measured from QUEST and MOCS procedures were not significantly different (QUEST: 1.05 arcmin2, P = 0.36 for session 1 and P = 0.41 for session 2; MOCS: 30.4 arcmin2, P = 0.14 for session 1 and P = 0.12 for session 2). Data were thus combined across paradigms for tests of repeatability. Sensitivities for data split into two groups within session 1 and separately within session 2 were not significantly different (QUEST: 1.05 arcmin2, P = 0.34 for session 1 and P = 0.51 for session 2; MOCS: 30.4 arcmin2, P = 0.31 for session 1 and P = 0.27 for session 2). Overall, sensitivities across the two sessions were not significantly different (QUEST: 1.05 arcmin2, P = 0.06; MOCS: 30.4 arcmin2, P = 0.81). The coefficients of repeatability across sessions were 1.5 decibels (dB) and 0.4 dB for 1.05 arcmin2 and 30.4 arcmin2, respectively.
Conclusions
Sensitivity measurements from AO microperimetry were repeatable within and across sessions. Translational Relevance: Results of the present study will guide future longitudinal studies of disease progression in detecting sensitivity changes using AO microperimetry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Bioengineering Graduate Group, University of Pennsylvania, Philadelphia, PA, USA.
- Herbert Wertheim School of Optometry and Vision Science, University of California, Berkeley, Berkeley, CA, USA.
- Department of Psychology, University of Pennsylvania, Philadelphia, PA, USA.
- Scheie Eye Institute, Department of Ophthalmology, University of Pennsylvania, Philadelphia, PA, USA.
- Center for Advanced Retinal and Ocular Therapeutics, University of Pennsylvania, Philadelphia, PA, USA.
Förderung
- NEI NIH HHS
Zitieren
APA
Govindasamy, N., Tuten, W. S., Brainard, D. H., & Morgan, J. I. W. (2026). Repeatability of Foveal Sensitivity Measured Using Adaptive Optics Microperimetry. Translational Vision Science & Technology, 15(8), 3. https://doi.org/10.1167/tvst.15.8.3
Vancouver
Govindasamy N, Tuten WS, Brainard DH, Morgan JIW. Repeatability of Foveal Sensitivity Measured Using Adaptive Optics Microperimetry. Translational Vision Science & Technology. 2026;15(8):3. doi:10.1167/tvst.15.8.3
BibTeX
@article{Govindasamy2026,
author = {Govindasamy, Nivedhitha and Tuten, William S and Brainard, David H and Morgan, Jessica I W},
title = {Repeatability of Foveal Sensitivity Measured Using Adaptive Optics Microperimetry},
journal = {Translational Vision Science & Technology},
year = {2026},
volume = {15},
number = {8},
pages = {3},
doi = {10.1167/tvst.15.8.3}
}