Scan Density Matters: Reproducibility of AI-Derived OCT Biomarkers in Diabetic Macular Edema
Translational Vision Science & Technology · 2026
DOI: 10.1167/tvst.15.5.12 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2026. Verfasst von Massimiliano Cocuzza und 6 weiteren Autor:innen. Beteiligte Einrichtung: University of Catania, Azienda Policlinico G. Rodolico-S. Marco, Catania, Italy. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Macular Edema, Diabetic Retinopathy, Artificial Intelligence. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To determine how optical coherence tomography (OCT) scan density affects quantification of artificial intelligence (AI)-derived structural biomarkers in diabetic macular edema (DME) and to identify density thresholds beyond which biomarker fidelity is compromised.
Methods
In this cross-sectional study, 401 DME eyes underwent three same-session OCT acquisitions using 97-, 49-, and 25-B-scan raster protocols on a single device. A CE-certified deep learning pipeline quantified intraretinal fluid (IRF) volume, subretinal fluid (SRF) volume, inflammatory hyperreflective foci (I-HRF), and photoreceptor integrity metrics. Linear mixed-effects models assessed density effects, Bland-Altman analyses quantified fixed and proportional bias, and volumetric thresholds were computed for deviations beyond ±0.10 mm³. Acquisition efficiency integrated biomarker variability and scan time.
Results
A total of 9624 biomarker measurements were analyzed with >98% completeness. SRF volume, I-HRF counts, and photoreceptor integrity metrics were stable across scan densities. IRF volume was density-dependent: the 25-scan protocol overestimated IRF relative to 97- and 49-scan acquisitions (mean bias -0.077 and -0.079 mm³; both P < 0.001), whereas 97- and 49-scan measurements were interchangeable. Overestimation increased with fluid burden (IRF threshold ∼1.1 mm³). Although the 25-scan protocol was fastest (10.7 seconds vs. 23.6 seconds and 50.3 seconds), the 49-scan protocol provided the best balance between speed and precision.
Conclusions
Most AI-derived OCT biomarkers in DME are robust to reduced scan density, but IRF volume shows increasing error with undersampling. Higher-density scans should be reserved when precise fluid quantification is required. Translational Relevance: Scan density materially influences AI-derived IRF quantification. Identifying practical acquisition thresholds enables protocol standardization while reducing imaging burden in clinical practice and trials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- University of Catania, Azienda Policlinico G. Rodolico-S. Marco, Catania, Italy.
- Iranian Research Center for HIV/AIDS, Iranian Institute for Reduction of High-Risk Behaviors, Tehran University of Medical Sciences, Tehran, Iran.
- Translational Ophthalmology Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.
- School of Medicine, Vita-Salute San Raffaele University, Milan, Italy.
- Department of Ophthalmology, IRCCS San Raffaele Scientific Institute, Milan, Italy.
- Department of Ophthalmology, University of Padova, Padova, Italy.
Zitieren
APA
Cocuzza, M., Ziafati, M., Lattanzio, R., Midena, E., Bandello, F., Cicinelli, M. V., & Current Research Directions in Ophthalmology Working Group (2026). Scan Density Matters: Reproducibility of AI-Derived OCT Biomarkers in Diabetic Macular Edema. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.15.5.12
Vancouver
Cocuzza M, Ziafati M, Lattanzio R, Midena E, Bandello F, Cicinelli MV, et al. Scan Density Matters: Reproducibility of AI-Derived OCT Biomarkers in Diabetic Macular Edema. Translational Vision Science & Technology. 2026. doi:10.1167/tvst.15.5.12
BibTeX
@article{Cocuzza2026,
author = {Cocuzza, Massimiliano and Ziafati, Makan and Lattanzio, Rosangela and Midena, Edoardo and Bandello, Francesco and Cicinelli, Maria Vittoria and Current Research Directions in Ophthalmology Working Group, Current Research Directions in Ophthalmology Working Group},
title = {Scan Density Matters: Reproducibility of AI-Derived OCT Biomarkers in Diabetic Macular Edema},
journal = {Translational Vision Science & Technology},
year = {2026},
doi = {10.1167/tvst.15.5.12}
}
EUVIMED