EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Potential Value of Novel Lipid-Derived Indicator as a Biomarker for Nonarteritic Anterior Ischemic Optic Neuropathy

Chenyang Cong, Wentong Yan, Yongqing Liu, Jingyao Song, Xuejiao Qin, Bing Liu

Translational Vision Science & Technology · 2026

DOI: 10.1167/tvst.15.2.7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2026. Verfasst von Chenyang Cong und 5 weiteren Autor:innen. Beteiligte Einrichtung: Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, Jinan, China. Hauptthemen laut MEDLINE: Optic Neuropathy, Ischemic, Biomarkers, Lipids. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to assess the role of novel lipid-related indices in patients with nonarteritic anterior ischemic optic neuropathy (NAION) and investigate the correlation between these indices and NAION severity.

Methods

All participants underwent comprehensive ocular examinations and serum lipid analysis. Novel lipid-related indices, including the atherogenic index of plasma (AIP), non-high-density lipoprotein cholesterol (HDL-C)/HDL-C ratio, and triglyceride glucose (TyG) index, were calculated using traditional lipid parameters and subsequently compared between patients with NAION and control participants. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the predictive values of these indices. Correlations between novel lipid-related indices and NAION severity were also investigated.

Results

Forty-four patients with NAION and 42 control participants were included in this study. The levels of AIP and TyG were significantly elevated in patients with NAION compared to control participants, whereas the traditional lipid parameters in both groups remained within normal limits. The areas under the ROC curves for AIP and TyG were 0.725 and 0.758, respectively. Additionally, no significant correlations were observed among AIP, TyG, best-corrected visual acuity, peripapillary retinal nerve fiber layer thickness, and mean deviation on visual field test.

Conclusions

Elevated levels of AIP and TyG were observed in patients with NAION in this study, suggesting that AIP and TyG may serve as systemic metabolic risk markers significantly associated with NAION. Translational Relevance: The findings of this study help us better understand the underlying mechanisms of NAION and improve its diagnosis and management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Optic Neuropathy, IschemicBiomarkersLipidsHumansFemaleMaleMiddle AgedROC CurveAgedVisual AcuityTriglyceridesVisual FieldsTomography, Optical Coherence

Substanzen

BiomarkersLipidsTriglycerides

Autor:innen und Institutionen

  • Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, Jinan, China.
  • Department of Ophthalmology, Jiyang People's Hospital, Jinan, China.
  • Department of Ophthalmology, Shandong Second Provincial General Hospital, Jinan, China.
  • Department of Ophthalmology, The Second Hospital, Cheeloo College of Medicine, Shandong University, Jinan, China.

Zitieren

APA

Cong, C., Yan, W., Liu, Y., Song, J., Qin, X., & Liu, B. (2026). Potential Value of Novel Lipid-Derived Indicator as a Biomarker for Nonarteritic Anterior Ischemic Optic Neuropathy. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.15.2.7

Vancouver

Cong C, Yan W, Liu Y, Song J, Qin X, Liu B. Potential Value of Novel Lipid-Derived Indicator as a Biomarker for Nonarteritic Anterior Ischemic Optic Neuropathy. Translational Vision Science & Technology. 2026. doi:10.1167/tvst.15.2.7

BibTeX
@article{Cong2026,
  author = {Cong, Chenyang and Yan, Wentong and Liu, Yongqing and Song, Jingyao and Qin, Xuejiao and Liu, Bing},
  title = {Potential Value of Novel Lipid-Derived Indicator as a Biomarker for Nonarteritic Anterior Ischemic Optic Neuropathy},
  journal = {Translational Vision Science & Technology},
  year = {2026},
  doi = {10.1167/tvst.15.2.7}
}
Kostenlos starten →